视频喉镜与纤维支气管镜用于清醒气管插管的系统评价与荟萃分析
该系统评价与荟萃分析比较了视频喉镜与纤维支气管镜用于清醒气管插管的效果,纳入8项研究共429例患者。主要结局插管时间在视频喉镜组更短,平均差(95%CI)为-45.7(-66.0至-25.4)秒,p<0.0001,证据质量低。两种技术在失败率、首次尝试成功率、患者满意度及不良事件方面无显著差异。
要点
- 视频喉镜用于清醒气管插管较纤维支气管镜缩短插管时间。
- 两种技术在插管失败率与首次尝试成功率上无显著差异。
- 患者满意度及声音嘶哑/咽喉痛、低氧饱和度发生率相似。
核心结论
- 视频喉镜用于清醒气管插管与更短的插管时间相关,且成功率与安全性似乎与纤维支气管镜相当。
研究设计与样本
- 系统评价与荟萃分析,纳入8项研究共429例患者。
主要发现
- 插管时间:视频喉镜组更短(7项试验,408例参与者,平均差(95%CI)-45.7(-66.0至-25.4)秒,p<0.0001,低质量证据)。
- 插管失败率:两组无显著差异(6项研究,355例参与者,风险比(95%CI)1.01(0.24-4.35),p=0.99,低质量证据)。
- 首次尝试成功率:两组无显著差异(6项研究,391例参与者,风险比(95%CI)1.01(0.95-1.06),p=0.8,中等质量证据)。
- 患者满意度:两组相似。
- 不良事件:声音嘶哑/咽喉痛(3项研究,167例参与者,风险比(95%CI)1.07(0.62-1.85),p=0.81,低质量证据)和低氧饱和度(5项研究,337例参与者,风险比(95%CI)0.49(0.22-1.12),p=0.09,低质量证据)无差异。
临床怎么用
- 在预期困难气道需清醒气管插管时,视频喉镜可作为一种与纤维支气管镜成功率及安全性相当且插管时间更短的选择。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Awake fibreoptic intubation is often considered the technique of choice when a difficult airway is anticipated. However, videolaryngoscopes are being used more commonly. We searched the current literature and performed a meta-analysis to compare the use of videolaryngoscopy and fibreoptic bronchoscopy for awake tracheal intubation. Our primary outcome was the time needed to intubate the patient's trachea. Secondary outcomes included: failed intubation; the rate of successful intubation at the first attempt; patient-reported satisfaction with the technique; and any complications resulting from intubation. Eight studies examining 429 patients were included in this review. The intubation time was shorter when videolaryngoscopy was used instead of fibreoptic bronchoscopy (seven trials, 408 participants, mean difference (95%CI) -45.7 (-66.0 to -25.4) s, p < 0.0001, low-quality evidence). There was no significant difference between the two techniques in the failure rate (six studies, 355 participants, risk ratio (95%CI) 1.01 (0.24-4.35), p = 0.99, low-quality evidence) or the first-attempt success rate (six studies, 391 participants, risk ratio (95%CI) 1.01 (0.95-1.06), p = 0.8, moderate quality evidence). The level of patient satisfaction was similar between both groups. No difference was found in two reported adverse events: hoarseness/sore throat (three studies, 167 participants, risk ratio (95%CI) 1.07 (0.62-1.85), p = 0.81, low-quality evidence), and low oxygen saturation (five studies, 337 participants, risk ratio (95%CI) 0.49 (0.22-1.12), p = 0.09, low-quality evidence). In summary, videolaryngoscopy for awake tracheal intubation is associated with a shorter intubation time. It also seems to have a success rate and safety profile comparable to fibreoptic bronchoscopy.
引用
- Alhomary M, Ramadan E, Curran E, et al. Videolaryngoscopy vs. fibreoptic bronchoscopy for awake tracheal intubation: a systematic review and meta-analysis. Anaesthesia. 2018. PMID: 29687891. doi:10.1111/anae.14299
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。