胶体预充联合晶体共充与单用晶体共充在剖宫产腰麻中的随机对照试验
下腔静脉超声可可靠评估,两组直径变化不同。
要点
- 胶体预充联合晶体共充未减少麻黄素总剂量或改善母婴结局。
- 两组低血压发生率、严重低血压及新生儿Apgar评分无显著差异。
- 下腔静脉超声在剖宫产术前及术中可可靠测量,两组直径变化不同。
核心结论
- 与1000 mL晶体共充相比,500 mL胶体预充联合500 mL晶体共充未减少麻黄素总剂量或改善其他母体结局。
主要发现
- 两组需要麻黄素的患者数、低血压和严重低血压发生率、首次麻黄素给药时间、新生儿1和5分钟Apgar评分均无显著差异。
- 两组下腔静脉最大和最小直径在腰麻后及分娩后均增加,联合组较大;分娩后下腔静脉塌陷指数晶体共充组较高。
关键数值与推荐
- 收缩压低于基线90%时给予麻黄素3 mg,低于80%(低血压)时5 mg,低于70%(严重低血压)时10 mg。
- 下腔静脉塌陷指数计算公式:IVC-CI =(最大IVC直径-最小IVC直径)/最大IVC直径。
临床怎么用
- 对于择期剖宫产腰麻,500 mL胶体预充联合500 mL晶体共充与1000 mL晶体共充在麻黄素需求和母婴结局上无显著差异,液体方案选择可个体化。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The optimal strategy of fluid administration during spinal anesthesia for cesarean delivery is still unclear. Ultrasonography of the inferior vena cava (IVC) has been recently used to assess the volume status and predict fluid responsiveness. In this double-blind, randomized controlled study, we compared maternal hemodynamics using a combination of 500-mL colloid preload and 500-mL crystalloid coload versus 1000-mL crystalloid coload. We assessed the IVC at baseline and at subsequent time points after spinal anesthesia. METHODS: Two hundred American Society of Anesthesiologists physical status II parturients with full-term singleton pregnancies scheduled for elective cesarean delivery under spinal anesthesia were randomly allocated to receive either 500-mL colloid preload followed by 500-mL crystalloid coload (combination group) or 1000-mL crystalloid coload (crystalloid coload group) administered using a pressurizer. Ephedrine 3, 5, and 10 mg boluses were administered when the systolic blood pressure decreased below 90%, 80% (hypotension), and 70% (severe hypotension) of the baseline value, respectively. The IVC was assessed using the subcostal long-axis view at baseline, at 1 and 5 minutes after intrathecal injection, and immediately after delivery; the maximum and minimum IVC diameters were measured, and the IVC collapsibility index (CI) was calculated using the formula: IVC-CI = (maximum IVC diameter - minimum IVC diameter)/maximum IVC diameter. The primary outcome was the total ephedrine dose. RESULTS: Data from 198 patients (99 patients in each group) were analyzed. The median (range) of the total ephedrine dose was 11 (0-60) mg in the combination group and 13 (0-61) mg in the crystalloid coload group; the median of the difference (95% nonparametric confidence interval) was -2 (-5 to 0.00005) mg, P = .22. There were no significant differences between the 2 groups in the number of patients requiring ephedrine, the incidence of hypotension and severe hypotension, the time to the first ephedrine dose, and neonatal Apgar scores at 1 and 5 minutes. The maximum and minimum IVC diameters in each group increased after spinal anesthesia and after delivery, and they were larger in the combination group. The IVC-CI after delivery was higher in the crystalloid coload group. CONCLUSIONS: The combination of 500-mL colloid preload and 500-mL crystalloid coload did not reduce the total ephedrine dose or improve other maternal outcomes compared with 1000-mL crystalloid coload. The IVC was reliably viewed before and during cesarean delivery, and its diameters significantly changed over time and differed between the 2 groups.
引用
- Tawfik MM, Tarbay AI, Elaidy AM, et al. Combined Colloid Preload and Crystalloid Coload Versus Crystalloid Coload During Spinal Anesthesia for Cesarean Delivery: A Randomized Controlled Trial. Anesth Analg. 2019. PMID: 29461392. doi:10.1213/ANE.0000000000003306
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。