感染预防组合措施降低麻醉工作环境污染的模拟研究
组合措施包括插管前双层手套、气道设备集中于一个区域、接触麻醉推车前手卫生。干预与受试者污染评分下降4.0(95%CI 2.2-5.6;P<.001)相关,评分较基线降低27%,完成时间无显著差异。
要点
- 感染预防组合措施可降低麻醉工作环境污染评分,且不延长操作时间。
- 喉镜柄等部分位点在干预后仍普遍受污染。
- 药物注射器与麻醉推车的污染在干预后显著减少。
核心结论
- 研究结果支持感染预防组合措施可减少麻醉工作环境污染的概念。
- 将手卫生与给药等高风险任务关联、划定污染设备区域、气道管理前双层手套是简单可快速实施的步骤。
研究设计与样本
- 受试者在模拟手术间完成基线场景和实施组合措施的干预场景共2个全身麻醉场景。
- 干预组合包括插管前双层手套、所有气道设备集中于1个区域、接触麻醉推车前执行手卫生。
- 每个场景前用紫外线荧光示踪剂标记模型口咽部和面部,场景后用紫外光源检查20个位点并由盲法观察者评分。
- 分析场景视频中手卫生与摘手套事件的时长和次数,数据采用混合效应模型分析。
主要发现
- 干预与受试者污染评分下降4.0(95%CI 2.2-5.6;P<.001)相关,基线至干预场景评分降低27%。
- 部分位点尽管实施干预仍普遍受污染,例如喉镜柄。
- 干预对减少药物注射器和麻醉推车的污染有统计学显著影响。
- 完成基线场景与干预场景所需时间无显著差异。
- 大多数受试者认为模拟场景有重要价值并将影响其未来临床行为。
临床怎么用
- 可将手卫生与给药等特定高风险任务绑定,并划定污染设备专用区域。
- 气道管理前采用双层手套,作为可快速实施且不延误患者照护的感染预防措施。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Microbiological contamination of the anesthesia work environment (AWE) is a potential source of health care-associated infections. Medication syringes, stopcocks, and many other areas are routinely contaminated during anesthetic care, and adherence to hand hygiene recommendations is poor. Using a simulation model, we investigated whether AWE contamination could be reduced by implementing an intervention bundle focused on infection prevention. METHODS: Twenty-five anesthesia providers were enrolled in this nonrandomized simulation scenario crossover design study. Subjects were asked to complete 2 general anesthesia scenarios in a mock operating room: a baseline scenario and an intervention scenario in which the bundle was implemented. The bundle included: double gloving before intubation, confining all airway equipment to 1 area, and performing hand hygiene before touching the anesthesia cart. Before each scenario, a manikin's oropharynx and face were marked with ultraviolet fluorescent tracers. After each scenario, the AWE was inspected with a ultraviolet light source to detect contaminant, and all sites were photographed. A blinded observer scored the images for the presence or absence of tracer at 20 sites. Videos of the scenarios were analyzed for duration and number of hand hygiene and glove removal events. Data were analyzed using a mixed effects model. Subjects completed a survey about their experience and the value of the scenarios. RESULTS: The intervention was associated with a decreased subject contamination score of 4.0 (95% confidence interval, 2.2-5.6; P < .001), a 27% reduction in score between baseline and intervention scenarios. Some sites were universally contaminated despite the intervention (eg, laryngoscope handles). The intervention had a statistically significant impact on reducing contamination on medication syringes and the anesthesia cart. There was no significant difference in time needed to complete baseline and intervention scenarios. The majority of subjects felt that the simulations had significant value and would affect their future clinical behavior. CONCLUSIONS: Our results support the concept of an infection prevention bundle in reducing AWE contamination. Anesthesia providers deliver care in a unique environment in which "clean" and "contaminated" tasks are performed rapidly and often in parallel. Linking hand hygiene to specific high-impact tasks such as administering medications, designating areas for contaminated equipment, and double gloving before airway management are simple steps that can be implemented rapidly and are compatible with timely patient care. Our study has improved awareness of infection prevention issues in our department, and has highlighted simple and achievable actions that have the potential to reduce health care-associated infections.
引用
- Porteous GH, Bean HA, Woodward CM, et al. A Simulation Study to Evaluate Improvements in Anesthesia Work Environment Contamination After Implementation of an Infection Prevention Bundle. Anesth Analg. 2018. PMID: 29283921. doi:10.1213/ANE.0000000000002764
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。