文献速递气道管理

视频喉镜用于院前急救插管:三种镜片类型的前瞻性随机多中心比较

Videolaryngoscopy for Physician-Based, Prehospital Emergency Intubation: A Prospective, Randomized, Multicenter Comparison of Different Blade Types Using A.P. Advance, C-MAC System, and KingVision.
PubMed 文献 · Anesth Analg · 2018-01-01

结果显示三种设备声门显露相当,但KingVision的总体插管成功率和首次尝试成功率均显著低于A.P. Advance和C-MAC。

要点

  • A.P. Advance与C-MAC总体插管成功率相近(96% vs 97%),KingVision仅61%。
  • 首次尝试成功率A.P. Advance为86%、C-MAC为85%,KingVision为48%。
  • 三种设备声门显露相当,但KingVision因通道式镜片实际插管更困难。

核心结论

  • 在急诊医生实施的院前紧急气管插管中,三种市售视频喉镜的插管成功率存在显著差异。
  • 尽管三种视频喉镜均能提供足够的声门视野,但通道式镜片KingVision的实际插管更困难。

研究设计与样本

  • 前瞻性、随机、多中心研究,在德国4个院前急救医学中心开展。
  • 主要结局为总体插管成功率,次要结局包括首次尝试插管成功率、声门可视化和设备操作困难度。
  • 两两比较的P值采用Bonferroni法校正(P[BF]),所有呈现的P值均按中心校正。

主要发现

  • 三种设备的声门可视化相当。
  • 总体插管成功率:A.P. Advance为96%,C-MAC为97%,KingVision为61%(总体P < .001)。
  • A.P. Advance与C-MAC比较:OR 0.97,95%CI 0.13-7.42,P[BF] > 0.99;A.P. Advance与KingVision比较:OR 0.043,95%CI 0.0088-0.21,P[BF] < 0.001;C-MAC与KingVision比较:OR 0.043,95%CI 0.0088-0.21,P[BF] < 0.001。
  • 首次尝试插管成功率:A.P. Advance为86%,C-MAC为85%,KingVision为48%(总体P < .001)。

临床怎么用

  • 院前紧急插管时,选择视频喉镜应优先考虑非通道式镜片设备(如A.P. Advance或C-MAC),而非通道式KingVision。
  • 即使视频喉镜提供良好声门视野,也需警惕通道式镜片可能增加实际插管难度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Videolaryngoscopy is a valuable technique for endotracheal intubation. When used in the perioperative period, different videolaryngoscopes vary both in terms of technical use and intubation success rates. However, in the prehospital environment, the relative performance of different videolaryngoscopic systems is less well studied. METHODS: We conducted this prospective, randomized, multicenter study at 4 German prehospital emergency medicine centers. One hundred sixty-eight adult patients requiring prehospital emergency intubation were treated by an emergency physician and randomized to 1 of 3 portable videolaryngoscopes (A.P. Advance, C-MAC PM, and channeled blade KingVision) with different blade types. The primary outcome variable was overall intubation success and secondary outcomes included first-attempt intubation success, glottis visualization, and difficulty with handling the devices. P values for pairwise comparisons are corrected by the Bonferroni method for 3 tests (P[BF]). All presented P values are adjusted for center. RESULTS: Glottis visualization was comparable with all 3 devices. Overall intubation success for A.P. Advance, C-MAC, and KingVision was 96%, 97%, and 61%, respectively (overall: P < .001, A.P. Advance versus C-MAC: odds ratio [OR], 0.97, 95% confidence interval [CI], 0.13-7.42, P[BF] > 0.99; A.P. Advance versus KingVision: OR, 0.043, 95% CI, 0.0088-0.21, P[BF] < 0.001; C-MAC versus KingVision: OR, 0.043, 95% CI, 0.0088-0.21, P[BF] < 0.001). Intubation success on the first attempt with A.P. Advance, C-MAC, and KingVision was 86%, 85%, and 48%, respectively (overall: P < .001, A.P. Advance versus C-MAC: OR, 0.89, 95% CI, 0.31-2.53, P[BF] > 0.99; A.P. Advance versus KingVision: OR, 0.24, 95% CI, 0.055-0.38, P[BF] = 0.0054; C-MAC versus KingVision: OR, 0.21, 95% CI, 0.043-.34, P[BF] < 0.003). Direct laryngoscopy for successful intubation with the videolaryngoscopic device was necessary with the A.P. Advance in 5 patients, and with the C-MAC in 4 patients. In the KingVision group, 21 patients were intubated with an alternative device. CONCLUSIONS: During prehospital emergency endotracheal intubation performed by emergency physicians, success rates of 3 commercially available videolaryngoscopes A.P. Advance, C-MAC PM, and KingVision varied markedly. We also found that although any of the videolaryngoscopes provided an adequate view, actual intubation was more difficult with the channeled blade KingVision.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Cavus E, Janssen S, Reifferscheid F, et al. Videolaryngoscopy for Physician-Based, Prehospital Emergency Intubation: A Prospective, Randomized, Multicenter Comparison of Different Blade Types Using A.P. Advance, C-MAC System, and KingVision. Anesth Analg. 2018. PMID: 29239965. doi:10.1213/ANE.0000000000002735

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。