经鼻高流量氧疗与标准氧疗用于支气管镜清醒镇静的随机对照试验
该平行组随机对照试验在行支气管内超声清醒镇静的成人中比较经鼻高流量氧疗(30-70 l.min-1)与经咬口标准氧疗(10 l.min-1)。高流量组30例中4例、标准组30例中10例发生血氧饱和度下降,意向性分析差异无统计学意义(p = 0.07),符合方案分析差异有统计学意义(p = 0.047);高流量组预氧合后及术中最低血氧饱和度均更高。
要点
- 高流量组去饱和发生率4/30,标准组10/30,意向性分析差异无统计学意义(p = 0.07)。
- 高流量组预氧合后血氧饱和度中位数100(IQR 99-100),高于标准组的98(IQR 97-99),p = 0.0001。
- 高流量组术中最低血氧饱和度中位数97.5(IQR 94-99),高于标准组的92(IQR 88-95),p < 0.001。
核心结论
- 经鼻高流量氧疗可能减少某些原因导致的去饱和,但并不能在所有情况下防止低氧血症。
研究设计与样本
- 平行组随机对照试验,纳入拟行支气管内超声清醒镇静的成人,每组30例。
- 高流量组经鼻导管给予30-70 l.min-1氧疗,标准组经咬口给予10 l.min-1氧疗。
主要发现
- 去饱和(SpO2 < 90%)在高流量组为4/30,在标准组为10/30,意向性分析差异无统计学意义(p = 0.07)。
- 符合方案分析中去饱和差异有统计学意义(p = 0.047)。
- 预氧合后血氧饱和度中位数(IQR [范围])高流量组为100(99-100 [93-100]),标准组为98(97-99 [94-100]),p = 0.0001。
- 术中最低血氧饱和度中位数(IQR [范围])高流量组为97.5(94-99 [77-100]),标准组为92(88-95 [79-98]),p < 0.001。
- 其他次要结局无差异。
关键数值与推荐
- 去饱和定义为SpO2 < 90%。
- 高流量氧疗流量为30-70 l.min-1,标准氧疗流量为10 l.min-1。
临床怎么用
- 对支气管内超声清醒镇静患者可考虑经鼻高流量氧疗以改善氧合,但需注意其不能在所有情况下防止低氧血症。
局限性
- 原文未报告样本量计算、盲法及随机化细节等局限性信息。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Traditional conscious sedation for endobronchial ultrasound procedures places patients at risk of desaturation, and high-flow nasal oxygen may reduce the risk. We designed a parallel-group randomised controlled trial of high-flow nasal oxygen at a flow rate of 30-70 l.min-1 via nasal cannulae, compared with standard oxygen therapy at 10 l.min-1 via a bite block in adults planned for conscious sedation for endobronchial ultrasound. The primary outcome was the proportion of patients experiencing desaturation (defined as SpO2 < 90%). Secondary outcomes included oxygen saturation after pre-oxygenation, lowest oxygen saturation during procedure, number of hypoxic episodes, duration of hypoxia, end-procedure end-tidal CO2 , satisfaction scores and complications. Thirty participants were allocated to each group. Baseline patient characteristics, procedure time and anaesthetic agents used were similar between the groups. Desaturation occurred in 4 out of 30 patients allocated to the high-flow nasal oxygen group, compared with 10 out of 30 allocated to the standard oxygenation group, a non-significant difference (p = 0.07) with intention to treat analysis. The difference was significant (p = 0.047) when using a per-protocol analysis. Oxygen saturation after pre-oxygenation and the lowest oxygen saturation during procedure were significantly higher in the high-flow nasal oxygen group compared with the standard oxygenation group; median (IQR [range] 100 (99-100 [93-100]) vs. 98 (97-99 [94-100]), p = 0.0001 and 97.5 (94-99 [77-100]) vs. 92 (88-95 [79-98]), p < 0.001, respectively. There were no differences in other secondary outcomes. Although high-flow nasal oxygen may prevent desaturation due to some causes, it does not protect against hypoxaemia in all circumstances.