肥胖患者全麻中个体化呼气末正压的电阻抗断层成像随机对照试验
本研究为随机对照临床试验,纳入BMI≥35 kg m⁻²择期腹腔镜手术患者,比较 recruiting maneuver(RM)联合电阻抗断层成像(EIT)滴定的个体化PEEP(PEEP_IND)与无RM且PEEP 5 cm H₂O(PEEP_5)对氧合、区域通气分布及呼气末肺容积(EELV)的影响。结果显示PEEP_IND组拔管前PaO₂/FiO₂更高、EELV更大、驱动压更低且通气分布更均匀,但拔管后组间差异消失。
要点
- 肥胖患者全麻中RM联合个体化PEEP可改善氧合与EELV。
- 个体化PEEP平均为18.5 cm H₂O,驱动压降低6.7 cm H₂O。
- 拔管后上述获益消失,肺保护策略应覆盖术后。
核心结论
- 在肥胖患者中,RM联合个体化PEEP可恢复麻醉期间的EELV、区域通气分布和氧合。
- 这些差异在拔管后未持续,肺保护策略应包含术后阶段。
研究设计与样本
- 随机对照临床试验,纳入BMI≥35 kg m⁻²择期腹腔镜手术患者,PEEP_IND组25例、PEEP_5组25例。
- 通气设置:潮气量8 ml kg⁻¹预测体重;PEEP_IND组行RM后以电阻抗断层成像滴定PEEP,PEEP_5组无RM且PEEP为5 cm H₂O。
- 主要终点为动脉血氧分压与吸入氧分数比值(PaO₂/FiO₂)。
主要发现
- 插管后两组合计PaO₂/FiO₂下降15 kPa(95%CI 11-20 kPa,P<0.001),EELV下降1.2 L(95%CI 0.9-1.6 L,P<0.001)。
- PEEP_IND组平均(标准差)PEEP为18.5(5.6)cm H₂O。
- 拔管前PEEP_IND组PaO₂/FiO₂高23 kPa(95%CI 16-29 kPa,P<0.001),EELV大1.8 L(95%CI 1.5-2.2 L,P<0.001)。
- 拔管前PEEP_IND组驱动压低6.7 cm H₂O(95%CI 5.4-7.9 cm H₂O,P<0.001),区域通气分布较PEEP_5组更均匀。
- 拔管后两组间上述差异消失。
临床怎么用
- 对BMI≥35 kg m⁻²的腹腔镜手术患者,可考虑RM联合EIT滴定的个体化PEEP以改善术中氧合与肺容积。
- 个体化PEEP平均值约18.5 cm H₂O,需注意术后肺保护策略的延续。
局限性
- 原文未报告局限性陈述。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: General anaesthesia leads to atelectasis, reduced end-expiratory lung volume (EELV), and diminished arterial oxygenation in obese patients. We hypothesized that a combination of a recruitment manoeuvre (RM) and individualized positive end-expiratory pressure (PEEP) can avoid these effects. METHODS: Patients with a BMI ≥35 kg m -2 undergoing elective laparoscopic surgery were randomly allocated to mechanical ventilation with a tidal volume of 8 ml kg -1 predicted body weight and (i) an RM followed by individualized PEEP titrated using electrical impedance tomography (PEEP IND ) or (ii) no RM and PEEP of 5 cm H 2 O (PEEP 5 ). Gas exchange, regional ventilation distribution, and EELV (multiple breath nitrogen washout method) were determined before, during, and after anaesthesia. The primary end point was the ratio of arterial partial pressure of oxygen to inspiratory oxygen fraction ( P aO 2 / F iO 2 ). RESULTS: For PEEP IND ( n =25) and PEEP 5 ( n =25) arms together, P aO 2 / F iO 2 and EELV decreased by 15 kPa [95% confidence interval (CI) 11-20 kPa, P <0.001] and 1.2 litres (95% CI 0.9-1.6 litres, P <0.001), respectively, after intubation. Mean ( sd ) PEEP IND was 18.5 (5.6) cm H 2 O. In the PEEP IND arm, P aO 2 / F iO 2 before extubation was 23 kPa higher (95% CI 16-29 kPa; P <0.001), EELV was 1.8 litres larger (95% CI 1.5-2.2 litres; P <0.001), driving pressure was 6.7 cm H 2 O lower (95% CI 5.4-7.9 cm H 2 O; P <0.001), and regional ventilation was more equally distributed than for PEEP 5 . After extubation, however, these differences between the arms vanished. CONCLUSIONS: In obese patients, an RM and higher PEEP IND restored EELV, regional ventilation distribution, and oxygenation during anaesthesia, but these differences did not persist after extubation. Therefore, lung protection strategies should include the postoperative period. CLINICAL TRIAL REGISTRATION: German clinical trials register DRKS00004199, www.who.int/ictrp/network/drks2/en/ .
引用
- Nestler C, Simon P, Petroff D, et al. Individualized positive end-expiratory pressure in obese patients during general anaesthesia: a randomized controlled clinical trial using electrical impedance tomography. Br J Anaesth. 2017. PMID: 29045567. doi:10.1093/bja/aex192
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。