文献速递气道管理

儿科镜片Pentax-AWS与Ovassapian气道在纤维支气管镜插管中的比较:一项随机对照试验

Comparison of the paediatric blade of the Pentax-AWS and Ovassapian airway in fibreoptic tracheal intubation in patients with limited mouth opening and cervical spine immobilization by a semi-rigid neck collar: a randomized controlled trial.
PubMed 文献 · Br J Anaesth · 2017-01-01

结果显示AWS-FOB组插管时间显著更短(32 vs 50秒,中位差19秒,95%CI 14-25秒,P<0.001),纤维支气管镜操作更容易,且极少需要优化手法;两组首次插管成功率无显著差异。

要点

  • 在半硬颈托固定颈部且张口受限患者中,Pentax-AWS儿科镜片联合纤维支气管镜插管时间显著短于Ovassapian气道联合纤维支气管镜。
  • AWS-FOB组纤维支气管镜操作更容易,需颌 thrust 的比例显著低于OVA-FOB组(0% vs 87%)。
  • 两组首次插管成功率无显著差异,但AWS-FOB组可减少外部气道优化手法的使用。

核心结论

  • 与Ovassapian气道联合纤维支气管镜相比,Pentax Airway Scope儿科镜片联合纤维支气管镜可更快完成气管插管,并减少外部气道优化手法的使用。

主要发现

  • AWS-FOB组插管时间显著短于OVA-FOB组(32 vs 50秒;中位差19秒;95%CI 14-25秒;P<0.001)。
  • AWS-FOB组纤维支气管镜操作难度显著更低(原文表述为显著更容易)。
  • AWS-FOB组需颌 thrust 的比例为0%(0/45),OVA-FOB组为87%(39/45);需颌 thrust 联合移除前颈托的比例分别为2%(1/45)和4%(2/45)。
  • 首次插管成功率两组无显著差异:AWS-FOB组45例(100%),OVA-FOB组44例(98%)。

临床怎么用

  • 对于颈部经半硬颈托固定且张口受限的患者,可考虑使用Pentax Airway Scope儿科镜片联合纤维支气管镜进行气管插管,以缩短插管时间并减少外部手法需求。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We compared the performances of the paediatric blade of a Pentax Airway Scope and an Ovassapian airway in fibreoptic tracheal intubation in patients whose necks were stabilized by semi-rigid neck collars. METHODS: Ninety patients were enrolled in this prospective, open-label, randomized controlled trial. Patients were randomly allocated to one of two groups (Group OVA-FOB and Group AWS-FOB). The time to tracheal intubation, success rate of tracheal intubation, number of optimization manoeuvres (jaw thrust), and difficulty of manipulation of the fibreoptic bronchoscope were compared between the groups. RESULTS: The time to tracheal intubation was significantly shorter (32 vs 50 s; median difference 19 s; 95% confidence interval 14-25 s; P<0.001) and manipulation of the fibreoptic bronchoscope was significantly easier for Group AWS-FOB. Optimization manoeuvres were rarely required to facilitate fibreoptic tracheal intubation in Group AWS-FOB [jaw thrust, 0 (0%); jaw thrust with anterior neck collar removal, 1 (2%)] compared with that required in Group OVA-FOB [jaw thrust, 39 (87%); jaw thrust with anterior neck collar removal, 2 (4%)]. There was no significant difference in the success rate of tracheal intubation on the first attempt between groups [Group AWS-FOB, 45 (100%); Group OVA-FOB, 44 (98%)]. CONCLUSIONS: Combined use of the paediatric blade of a Pentax Airway Scope and a fibreoptic bronchoscope enabled rapid tracheal intubation, minimizing the use of external manoeuvres of the airway, in patients with limited mouth opening and cervical spine immobilization by semi-rigid neck collars, compared with use of the Ovassapian airway and the fibreoptic bronchoscope. CLINICAL TRIAL REGISTRATION: NCT02827110.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Kim DH, Yoo JY, Ha SY, et al. Comparison of the paediatric blade of the Pentax-AWS and Ovassapian airway in fibreoptic tracheal intubation in patients with limited mouth opening and cervical spine immobilization by a semi-rigid neck collar: a randomized controlled trial. Br J Anaesth. 2017. PMID: 28981579. doi:10.1093/bja/aex272

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。