小儿麻醉 Fellows 对带教监督质量与医疗差错的感知调查
9%报告曾在未充分培训下操作,13%报告对患者造成负面后果的差错,22%报告过去一年用药差错;带教监督评分与差错频率无关联。
要点
- 小儿麻醉 fellows 自我报告用药差错率较高(22%)。
- 感知的带教监督质量与报告差错频率无显著关联。
- 结果提示需评估疲劳、倦怠等其他与差错相关的因素。
核心结论
- 美国小儿麻醉 fellows 自我报告用药差错率较高,但感知的带教监督质量与报告差错频率无关联。
主要发现
- 103名中9名(9%,95%CI 4%-16%)报告在未充分培训下多次操作。
- 101名中13名(13%,95%CI 7%-21%)报告对患者造成负面后果的差错超过1次。
- 104名中23名(22%,95%CI 15%-31%)报告过去一年用药差错超过1次。
临床怎么用
- 小儿麻醉培训应关注 fellows 自我报告的用药差错及未充分培训下的操作问题。
- 仅靠提升带教监督感知可能不足以减少差错,需探索疲劳、倦怠等其他因素。
局限性
- 研究为问卷调查,依赖自我报告,可能存在回忆偏倚和社会期望偏倚。
- 回复率59%,样本来自53个项目,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Appropriate supervision has been shown to reduce medical errors in anesthesiology residents and other trainees across various specialties. Nonetheless, supervision of pediatric anesthesiology fellows has yet to be evaluated. The main objective of this survey investigation was to evaluate supervision of pediatric anesthesiology fellows in the United States. We hypothesized that there was an indirect association between perceived quality of faculty supervision of pediatric anesthesiology fellow trainees and the frequency of medical errors reported. METHODS: A survey of pediatric fellows from 53 pediatric anesthesiology fellowship programs in the United States was performed. The primary outcome was the frequency of self-reported errors by fellows, and the primary independent variable was supervision scores. Questions also assessed barriers for effective faculty supervision. RESULTS: One hundred seventy-six pediatric anesthesiology fellows were invited to participate, and 104 (59%) responded to the survey. Nine of 103 (9%, 95% confidence interval [CI], 4%-16%) respondents reported performing procedures, on >1 occasion, for which they were not properly trained for. Thirteen of 101 (13%, 95% CI, 7%-21%) reported making >1 mistake with negative consequence to patients, and 23 of 104 (22%, 95% CI, 15%-31%) reported >1 medication error in the last year. There were no differences in median (interquartile range) supervision scores between fellows who reported >1 medication error compared to those reporting ≤1 errors (3.4 [3.0-3.7] vs 3.4 [3.1-3.7]; median difference, 0; 99% CI, -0.3 to 0.3; P = .96). Similarly, there were no differences in those who reported >1 mistake with negative patient consequences, 3.3 (3.0-3.7), compared with those who did not report mistakes with negative patient consequences (3.4 [3.3-3.7]; median difference, 0.1; 99% CI, -0.2 to 0.6; P = .35). CONCLUSIONS: We detected a high rate of self-reported medication errors in pediatric anesthesiology fellows in the United States. Interestingly, fellows' perception of quality of faculty supervision was not associated with the frequency of reported errors. The current results with a narrow CI suggest the need to evaluate other potential factors that can be associated with the high frequency of reported errors by pediatric fellows (eg, fatigue, burnout). The identification of factors that lead to medical errors by pediatric anesthesiology fellows should be a main research priority to improve both trainee education and best practices of pediatric anesthesia.
引用
- Benzon HA, Hajduk J, De Oliveira G, et al. Pediatric Anesthesiology Fellows' Perception of Quality of Attending Supervision and Medical Errors. Anesth Analg. 2018. PMID: 28863019. doi:10.1213/ANE.0000000000002445
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。