文献速递区域麻醉与超声产科麻醉

硬膜外容积扩展对鞘内局麻药效能与安全性的系统评价与荟萃分析

Effects of epidural volume extension by saline injection on the efficacy and safety of intrathecal local anaesthetics: systematic review with meta-analysis, meta-regression and trial sequential analysis.
PubMed 文献 · Anaesthesia · 2017-09-11

该系统评价纳入15项随机对照试验共1177例手术患者,评估脊麻后硬膜外注射生理盐水行容积扩展的效果。主要结局如最高感觉平面和低血压发生率在组间无显著差异,证据质量低,试验序贯分析提示证据不充分;亚组分析显示不同麻醉混合液时运动阻滞恢复时间可能缩短。

要点

  • 硬膜外容积扩展对最高感觉平面和低血压发生率无显著影响,证据质量低
  • 容积扩展效应呈容量依赖性,高容量可能增加鞘内药物扩散和低血压发生率
  • 不同麻醉混合液时运动阻滞恢复时间可能缩短,需进一步研究

核心结论

  • 目前证据不足以对硬膜外容积扩展的效果得出明确结论,效能与安全性的证据质量均为低。

研究设计与样本

  • 系统评价与荟萃分析,纳入15项随机对照试验共1177例手术患者,比较脊麻后硬膜外注射生理盐水与不注射的对照。

主要发现

  • 最高感觉平面(6项研究,274例)平均差(95%CI)为-0.59(-1.24至0.07)皮节,证据质量低。
  • 低血压(10项研究,683例)风险比(95%CI)为0.84(0.66-1.07),证据质量低。
  • 荟萃回归提示容积依赖性效应,较高容量导致鞘内药物扩散更广和低血压发生率更高。
  • 亚组分析:较低麻醉剂量加容积扩展对比较高麻醉剂量无容积扩展,运动阻滞恢复时间平均差(95%CI)为-66.75(-76.0至-57.5)分钟,试验序贯分析认为证据充分。
  • 相同麻醉混合液试验中,运动阻滞恢复时间平均差(95%CI)为-1.06(-5.48至3.36)分钟,试验序贯分析提示证据不充分。

临床怎么用

  • 硬膜外容积扩展对感觉平面和低血压的影响不确定,临床决策需谨慎。
  • 若采用容积扩展,应注意容量相关风险,高容量可能增加低血压发生率。
  • 不同麻醉混合液时可能缩短运动阻滞恢复时间,但需进一步研究验证。

局限性

  • 纳入研究数量有限,部分结局证据质量低。
  • 试验序贯分析提示主要结局证据不充分。
  • 容积扩展效应受容量影响,异质性可能影响结果解释。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Epidural volume extension, a modification of combined spinal-epidural anaesthesia, involves the epidural injection of saline in order to increase the spread of drugs given intrathecally. Results from individual studies have so far been contradictory and we aimed to gather the available evidence for this technique. We performed a systematic literature search for randomised, controlled trials comparing epidural volume extension after spinal injection with a control group without epidural injection in patients undergoing surgery. Conventional meta-analyses, trial sequential analyses and meta-regression were performed, with the Grading of Recommendations on Assessment, Development and Evaluation (GRADE) approach used to express reliability of outcome estimates. We included 15 studies with 1177 participants. Meta-analyses for the primary outcomes, such as maximum sensory height (6 studies, 274 participants, mean difference (MD) (95%CI) -0.59 (-1.24 to 0.07) dermatomes, low-quality evidence) and hypotension (10 studies, 683 participants, risk ratio (95%CI) 0.84 (0.66-1.07), low-quality evidence), did not differ significantly between the two treatment arms, but trial sequential analysis suggested insufficient evidence to be certain of these findings. Meta-regression suggested a volume-dependent effect, with higher volumes causing a higher spread of intrathecal drugs and a higher incidence of hypotension. A sub-group analysis indicated a pronounced effect on motor block recovery time when a lower anaesthetic dose plus epidural volume extension was compared with a higher anaesthetic dose without epidural volume extension, the MD (95%CI) being -66.75 (-76.0 to -57.5) min, with trial sequential analysis suggesting the evidence was sufficient to draw this conclusion. In trials using the same anaesthetic mixture in the epidural volume extension and the control groups, motor block recovery time did not differ between groups, with a MD (95%CI) of -1.06 (-5.48 to 3.36) min, although trial sequential analysis suggested insufficient evidence. In summary, there is not enough evidence to draw definite conclusions on the effect of epidural volume extension. The quality of the current evidence is low for both efficacy (maximum sensory height) and safety (hypotension). However, there may be a significantly shorter motor block recovery time when different anaesthetic mixtures are used in epidural volume extension and control groups; this warrants further investigation.

来源:Anaesthesia,查看原文。版权归原作者所有。

引用

  1. Heesen M, Weibel S, Klimek M, et al. Effects of epidural volume extension by saline injection on the efficacy and safety of intrathecal local anaesthetics: systematic review with meta-analysis, meta-regression and trial sequential analysis. Anaesthesia. 2017. PMID: 28891203. doi:10.1111/anae.14033

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。