文献速递产科麻醉

硬膜外分娩镇痛芬太尼剂量与母乳喂养成功率:一项随机临床试验

Epidural Labor Analgesia-Fentanyl Dose and Breastfeeding Success: A Randomized Clinical Trial.
PubMed 文献 · Anesthesiology · 2017-01-01

该随机双盲对照试验纳入345名经产妇,比较三种硬膜外维持方案(布比卡因1 mg/ml、布比卡因0.8 mg/ml+芬太尼1 μg/ml、布比卡因0.625 mg/ml+芬太尼2 μg/ml),主要结局为产后6周母乳喂养比例。结果显示三组分别为97%、98%、94%(P=0.34),累计芬太尼剂量及母婴血药浓度在中断与持续母乳喂养者间无差异。结论认为含芬太尼高达2 μg/ml的硬膜外溶液不影响产后6周母乳喂养率。

要点

  • 硬膜外芬太尼浓度高达2 μg/ml不降低产后6周母乳喂养率。
  • 累计芬太尼剂量在中断与持续母乳喂养者间无显著差异。
  • 母婴芬太尼及布比卡因血药浓度与母乳喂养中断无关。

核心结论

  • 含芬太尼浓度高达2 μg/ml的分娩硬膜外溶液似乎不影响产后6周母乳喂养率。

研究设计与样本

  • 随机双盲对照试验,纳入345名大于38周妊娠、计划母乳喂养且既往成功母乳喂养的经产妇,305名有完整数据用于分析。

主要发现

  • 产后6周母乳喂养频率在芬太尼0、1、2 μg/ml组分别为97%、98%、94%(P=0.34)。
  • 中断与持续母乳喂养者间累计芬太尼剂量差异为37 μg(95%CI -58至79 μg,P=0.28)。
  • 中断与持续母乳喂养者间母体及脐静脉芬太尼和布比卡因浓度无差异。

临床怎么用

  • 分娩硬膜外镇痛使用含芬太尼高达2 μg/ml的溶液时,无需担心其对产后6周母乳喂养率的负面影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Breastfeeding is an important public health concern. High cumulative doses of epidural fentanyl administered for labor analgesia have been reported to be associated with early termination of breastfeeding. We tested the hypothesis that breastfeeding success is adversely influenced by the cumulative epidural fentanyl dose administered for labor analgesia. METHODS: The study was a randomized, double-blind, controlled trial of parous women at greater than 38 weeks gestation who planned to breastfeed, had successfully breastfed a prior infant, and who received neuraxial labor analgesia. Participants were randomized to receive one of three epidural maintenance solutions for labor analgesia (bupivacaine 1 mg/ml, bupivacaine 0.8 mg/ml with fentanyl 1 μg/ml, or bupivacaine 0.625 mg/ml with fentanyl 2 μg/ml). The primary outcome was the proportion of women breastfeeding at 6 weeks postpartum. Maternal and umbilical venous blood fentanyl and bupivacaine concentration at delivery were measured. RESULTS: A total of 345 women were randomized and 305 had complete data for analysis. The frequency of breastfeeding at 6 weeks was 97, 98, and 94% in the groups receiving epidural fentanyl 0, 1, and 2 μg/ml, respectively (P = 0.34). The cumulative fentanyl dose (difference: 37 μg [95% CI of the difference, -58 to 79 μg], P = 0.28) and maternal and umbilical cord venous fentanyl and bupivacaine concentrations did not differ between women who discontinued breastfeeding and those who were still breastfeeding at 6 weeks postpartum. CONCLUSIONS: Labor epidural solutions containing fentanyl concentrations as high as 2 μg/ml do not appear to influence breastfeeding rates at 6 weeks postpartum.

来源:Anesthesiology,查看原文。版权归原作者所有。

引用

  1. Lee AI, McCarthy RJ, Toledo P, et al. Epidural Labor Analgesia-Fentanyl Dose and Breastfeeding Success: A Randomized Clinical Trial. Anesthesiology. 2017. PMID: 28926440. doi:10.1097/ALN.0000000000001793

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。