可吞服遥测传感器监测产科脊髓麻醉中的核心体温
BACKGROUND: Perioperative hypothermia may affect maternal and neonatal outcomes after obstetric spinal anesthesia. Core temperature is often poorly monitored during spinal anesthesia, due to the lack of an accurate noninvasive core temperature monitor.…
要点
- 脊髓麻醉后核心体温快速下降,平均降幅1.30°C。
- 半数产妇体温低于36.0°C,低体温暴露持续数小时。
- 部分产妇体温在监测期内未恢复至基线。
研究设计与样本
- 描述性研究,纳入28例择期剖宫产脊髓麻醉产妇,使用可吞服遥测温度传感器每10秒记录核心体温。
主要发现
- 脊髓麻醉注药后肠道温度平均下降1.30°C(标准差0.31),99%CI为1.14至1.46。
- 体温最低点中位时间0.96小时(IQR 0.73-1.32),95%CI为0.88-1.22。
- 28例中14例注药后肠道温度低于36.0°C。
- 28例中8例在监测期内肠道温度未恢复至基线;其余20例恢复至基线中位时间4.59小时(IQR 3.38-5.92),95%CI为3.45-5.90。
- 低体温暴露中位1.97度-小时(IQR 1.00-2.68),95%CI为1.23-2.45;每小时低于37.0°C的中位度数为0.45(IQR 0.35-0.60),95%CI为0.36-0.58。
临床怎么用
- 剖宫产脊髓麻醉期间应重视核心体温监测,警惕快速体温下降和持续低体温暴露。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Perioperative hypothermia may affect maternal and neonatal outcomes after obstetric spinal anesthesia. Core temperature is often poorly monitored during spinal anesthesia, due to the lack of an accurate noninvasive core temperature monitor. The aim of this study was to describe core temperature changes and temperature recovery during spinal anesthesia for elective cesarean delivery. We expected that obstetric spinal anesthesia would be associated with a clinically relevant thermoregulatory insult (core temperature decrease >1.0°C). METHODS: A descriptive study was conducted in 28 women. An ingestible telemetric temperature sensor was used to record core temperature over time (measured every 10 seconds). The primary outcome was the maximum core temperature decrease after spinal anesthetic injection. The secondary outcomes were lowest absolute core temperature, time to lowest temperature, time to recovery of core temperature, hypothermic exposure (degree-hours below 37.0°C), and the time-weighted hypothermic exposure (median number of degrees below 37.0°C per hour). Basic descriptive statistics, median spline smooth, and integration of the area below the 37.0°C line of the temperature-over-time curve were utilized to analyze the data. RESULTS: Intestinal temperature decreased by a mean (standard deviation) of 1.30°C (0.31); 99% confidence interval (CI), 1.14 to 1.46 after spinal anesthetic injection. The median (interquartile range [IQR]) time to temperature nadir was 0.96 (0.73-1.32) hours (95% CI, 0.88-1.22). Fourteen of the 28 participants experienced intestinal temperatures below 36.0°C after spinal injection. Temperature was monitored for a minimum of 8 hours after spinal injection. In 8 of 28 participants, intestinal temperature did not recover to baseline during the monitored period. A median (IQR) of 4.59 (3.38-5.92) hours (95% CI, 3.45-5.90) was required for recovery to baseline intestinal temperature in the remaining 20 patients. Participants experienced a median (IQR) of 1.97 (1.00-2.68) degree-hours of hypothermic exposure (95% CI, 1.23-2.45). The median (IQR) number of degrees below 37.0°C per hour was 0.45 (0.35-0.60) (95% CI, 0.36-0.58). CONCLUSIONS: During cesarean delivery under spinal anesthesia, women experienced a rapid decrease in core temperature. Using an intestinal telemetric sensor, the perioperative thermal insult and recovery were documented with high resolution. Fifty percent of participants in this study became hypothermic. Although the surgical procedure is typically of short duration, women undergoing spinal anesthesia for cesarean delivery experience significant hypothermic exposure and compromised thermoregulation for several hours.
引用
- du Toit L, van Dyk D, Hofmeyr R, et al. Core Temperature Monitoring in Obstetric Spinal Anesthesia Using an Ingestible Telemetric Sensor. Anesth Analg. 2018. PMID: 28799968. doi:10.1213/ANE.0000000000002326
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。