文献速递产科麻醉区域麻醉与超声

硬膜穿刺硬膜外与硬膜外分娩镇痛起效比较:随机临床试验

Labor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: A Randomized Clinical Trial.
PubMed 文献 · Anesth Analg · 2018-01-01

该随机试验比较硬膜穿刺硬膜外(DPE)与腰椎硬膜外(LE)使用0.125%布比卡因推注的分娩镇痛起效速度。

要点

  • DPE组达到充分镇痛的中位时间更短(8分钟 vs 10分钟)。

核心结论

  • 使用0.125%布比卡因推注时,DPE与LE在10分钟时的充分镇痛率无差异,但DPE达到VAS≤10mm的时间更快。

研究设计与样本

  • 随机临床试验,最终分析80例(每组40例),纳入活跃宫缩时VAS≥50mm的产妇,随机接受LE或DPE。
  • 使用17G Tuohy针阻力消失法定位硬膜外间隙,DPE组用26G Whitacre针穿刺硬膜,所有参与者置入19G硬膜外导管。
  • 硬膜外推注12mL 0.125%布比卡因+50μg芬太尼(3分钟),随后输注0.1%布比卡因+2μg/mL芬太尼,推注开始后每2分钟测VAS至20分钟。

主要发现

  • 达到充分镇痛的中位时间(95%CI):DPE组8分钟(6-10),LE组10分钟(8-14)。

关键数值与推荐

  • 充分分娩镇痛定义为活跃宫缩时VAS≤10mm(100mm量表),在硬膜外推注开始后10分钟测量。
  • 纳入标准:活跃宫缩时VAS≥50mm的产妇。

临床怎么用

  • 在需快速起效的分娩镇痛场景中,DPE技术可考虑用于缩短达到充分镇痛的时间。
  • 使用0.125%布比卡因推注时,DPE与LE在10分钟时的镇痛成功率无显著差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Lumbar epidurals (LEs) provide excellent analgesia. Combined spinal epidural and dural puncture epidural (DPE) are 2 techniques to expedite neuraxial analgesia onset. In DPE, dura is punctured but medication is not administered in the cerebrospinal fluid. Expedited analgesia onset has been demonstrated with DPE, using 0.25% bupivacaine; however, this concentration may impede an unassisted vaginal birth and is not currently used for induction and maintenance of labor analgesia. The primary goal of this study was to compare the percentage of patients who achieved adequate labor analgesia following DPE or LE with an epidural bolus of 0.125% bupivacaine. Adequate labor analgesia was defined as Visual Analog Scale (VAS) measurement ≤ 10 mm on a 100-mm scale during active contractions, measured 10 minutes after epidural bolus initiation. METHODS: Laboring patients were randomly assigned to receive LE or DPE. Immediately before epidural placement, subjects marked a VAS score during an active contraction and parturients with VAS < 50 mm were excluded. The epidural space was identified by a loss of resistance technique to saline (17G Tuohy needle [Arrow International, Inc, Redding, PA]). In the DPE group, dura was punctured with a 26G Whitacre needle (Arrow International, Inc). In all participants, a 19G epidural catheter (Arrow International, Inc) was inserted. An epidural bolus was then administered over 3 minutes (12 mL, 0.125% bupivacaine, 50 μg fentanyl) followed by infusion (0.1% bupivacaine, 2 μg/mL fentanyl). After initiation of epidural bolus (time zero), VAS measurements were collected at 2-minute intervals for up to 20 minutes. Median time to achieve adequate analgesia by treatment group was assessed by Kaplan-Meier analysis. Time to achieving adequate analgesia was evaluated using a Cox regression model. All analyses were conducted in SAS version 9.4. (SAS Institute, Cary, NC) RESULTS:: Data were analyzed from 80 participants (40 per group). Adequate analgesia at 10 minutes did not differ by neuraxial technique (DPE = 55.3% vs LE = 44.7%; P= .256). However, parturients receiving DPE had shorter median times to adequate analgesia (median [95% confidence interval], 8 minutes [6-10] vs 10 minutes [8-14]) and a 67% increase in the relative risk of achieving adequate analgesia compared to LE (relative risk = 1.67; 95% confidence interval, 1.02-2.64; P= .042). CONCLUSIONS: Although the percentage of parturients achieving adequate labor analgesia at 10 minutes after epidural bolus did not differ by technique, DPE was associated with faster time to VAS ≤ 10 mm compared with LE.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Wilson SH, Wolf BJ, Bingham K, et al. Labor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: A Randomized Clinical Trial. Anesth Analg. 2018. PMID: 28622178. doi:10.1213/ANE.0000000000002129

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。