清醒纤维支气管镜插管实践的前瞻性队列研究
一项在三级中心进行的前瞻性队列研究,收集了600例择期或急诊清醒纤维支气管镜插管的数据,占需全麻手术患者的1.71%。主要适应证为张口受限(26.8%)和既往气道手术或头颈放疗(各22.5%)。失败率1.0%,并发症率11.0%,操作者经验与并发症显著相关。
要点
- 清醒纤支镜插管失败率1.0%,并发症率11.0%,最常见为多次尝试(4.2%)。
- 操作者既往操作次数越多,并发症越少。
- trainees作为主要操作者占78.6%,其中86.8%由顾问直接监督,并发症和成功率与顾问相似。
核心结论
- 清醒纤维支气管镜插管是安全且成功率高的操作。
- 机构内培训可培养和维持受训者的操作能力,并发症发生率和成功率与顾问相当。
研究设计与样本
- 前瞻性队列研究,在三级中心收集600例择期或急诊清醒纤维支气管镜插管的数据。
- 数据包括患者和操作者人口学信息、技术操作和并发症。
主要发现
- 清醒纤维支气管镜插管占需全麻手术患者的1.71%。
- 最常见适应证为张口受限(26.8%),其次为既往气道手术或头颈放疗(各22.5%)。
- 仅5例无镇静,最常用镇静技术为瑞芬太尼和丙泊酚靶控输注联合。
- 49.0%患者通过鼻导管接受高流量加温加湿氧疗。
- 失败率1.0%,并发症率11.0%,最常见并发症为多次尝试(4.2%)、过度镇静(2.2%)和血氧饱和度下降(1.5%)。
临床怎么用
- 清醒纤支镜插管可用于张口受限或既往气道手术/头颈放疗患者。
- 常用镇静为瑞芬太尼和丙泊酚靶控输注联合,氧疗可采用鼻导管高流量加温加湿氧。
- 培训中受训者在顾问监督下操作可获得与顾问相似的并发症和成功率。
局限性
- 单中心研究,结果可能不能推广到其他机构。
- 仅纳入600例,某些并发症发生率低,统计效能有限。
- 未报告长期结局或患者满意度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Contemporary data are lacking for procedural practice, training provision and outcomes for awake fibreoptic intubation in the UK. We performed a prospective cohort study of awake fibreoptic intubations at a tertiary centre to assess current practice. Data from 600 elective or emergency awake fibreoptic intubations were collected to include information on patient and operator demographics, technical performance and complications. This comprised 1.71% of patients presenting for surgery requiring a general anaesthetic, with the majority occurring in patients presenting for head and neck surgery. The most common indication was reduced mouth opening (26.8%), followed by previous airway surgery or head and neck radiotherapy (22.5% each). Only five awake fibreoptic intubations were performed with no sedation, but the most common sedative technique was combined target-controlled infusions of remifentanil and propofol. Oxygenation was achieved with high-flow, heated and humidified oxygen via nasal cannula in 49.0% of patients. Most operators had performed awake fibreoptic intubation more than 20 times previously, but trainees were the primary operator in 78.6% of awake fibreoptic intubations, of which 86.8% were directly supervised by a consultant. The failure rate was 1.0%, and 11.0% of awake fibreoptic intubations were complicated, most commonly by multiple attempts (4.2%), over-sedation (2.2%) or desaturation (1.5%). The only significant association with complications was the number of previous awake fibreoptic intubations performed, with fewer complications occurring in the hands of operators with more awake fibreoptic intubation experience. Our data demonstrate that awake fibreoptic intubation is a safe procedure with a high success rate. Institutional awake fibreoptic intubation training can both develop and maintain trainee competence in performing awake fibreoptic intubation, with a similar incidence of complications and success compared with consultants.
引用
- El-Boghdadly K, Onwochei DN, Cuddihy J, et al. A prospective cohort study of awake fibreoptic intubation practice at a tertiary centre. Anaesthesia. 2017. PMID: 28654138. doi:10.1111/anae.13844
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。