Glidescope与Airtraq DL在预测或已知困难气道患者中双腔气管插管比较:随机研究
该随机研究比较Glidescope与Airtraq DL在预测或已知困难气道患者中双腔气管插管的效果。共纳入72例患者,两组两次尝试内插管总成功率无差异(86% vs 94%,P=0.43),声门显露、插管时间及副作用亦无差异。结论认为两种器械插管成功率无差别。
要点
- 在预测或已知困难气道患者中,Glidescope与Airtraq DL双腔管插管成功率无显著差异。
- 两组首次尝试成功率、Cormack-Lehane分级、插管时间及副作用均无差异。
- 有困难插管史的患者均插管成功。
核心结论
- 在预测或已知困难气道患者中,使用Glidescope或Airtraq DL进行双腔气管插管的总成功率无差异。
研究设计与样本
- 随机研究,纳入72例择期胸科手术需单肺通气且Arné评分≥7或已知困难插管的成人患者。
主要发现
- 两次尝试内插管总成功率:Glidescope组31/36(86%),Airtraq组34/36(94%),P=0.43。
- 插管时间:Glidescope组67秒(49-90),Airtraq组81秒(59-101),P=0.28。
- Cormack-Lehane分级两组无差异(P=0.18),副作用无差异。
- 有困难插管史的患者全部插管成功。
临床怎么用
- 对于预测或已知困难气道需双腔气管插管的患者,Glidescope与Airtraq DL均可作为选择,成功率相当。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Double-lumen tracheal tube (DLT) insertion can be managed with videolaryngoscopes such as the Glidescope or indirect laryngoscopes like the Airtraq DL. No study has compared both devices when a difficult intubation is predicted. OBJECTIVE: Our hypothesis was that the Glidescope is superior to the Airtraq for double-lumen tube insertion in patients with a predicted or known difficult airway. DESIGN: Randomised study. PATIENTS: Adults scheduled for thoracic elective surgery, requiring one-lung ventilation with a predicted difficult intubation score of at least 7 (Arné risk index). INTERVENTION: Between March 2014 and March 2015, adult patients, scheduled for elective thoracic surgery, requiring double-lumen tracheal tube placement, and with a predicted risk (evaluated preoperatively using the Arné score) or a history of difficult intubation, were allocated to a Glidescope or an Airtraq group. MAIN OUTCOME MEASURES: The primary outcome was the overall success rate of tracheal intubation after two attempts. Secondary outcomes were success rates on the first attempt, duration of intubation, need for laryngeal pressure, Cormack and Lehane grade and side-effects. RESULTS: Of 277 patients, 78 were predicted to have a difficult airway. Finally, 72 patients were enrolled. Neither the overall success rates of tracheal intubation [Glidescope group 31/36 (86%) versus Airtraq group 34/36 (94%), P = 0.43] nor the side-effects differed between groups. There was no difference concerning visualisation of the glottis using the Cormack and Lehane grade (P = 0.18) or intubation time [Glidescope group 67 s (49 to 90) versus Airtraq group 81 s (59 to 101), P = 0.28]. All patients with a previous history of difficult intubation were intubated successfully. CONCLUSION: There is no difference in success rates of tracheal intubation with a double-lumen tube in patients with a predicted or known difficult airway when using either a Glidescope or Airtraq device. TRIAL REGISTRATION: National register of the French National Agency for Medicines and Health Products Safety No. 2014-A00143-44.
引用
- Belze O, Lepage E, Bazin Y, et al. Glidescope versus Airtraq DL for double-lumen tracheal tube insertion in patients with a predicted or known difficult airway: A randomised study. Eur J Anaesthesiol. 2017. PMID: 28525401. doi:10.1097/EJA.0000000000000655
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。