闭环反馈计算机控制去氧肾上腺素间断推注与持续输注用于剖宫产脊麻血压维持的随机试验比较
但组间差异小,临床结局无差异。
要点
- 计算机控制间断推注去氧肾上腺素较持续输注血压控制更精确,中位绝对执行误差更小。
- 推注组去氧肾上腺素用量更少,中位执行误差更小,提示平均收缩压略低。
- 两组心输出量、恶心呕吐及新生儿结局无差异。
核心结论
- 计算机控制去氧肾上腺素间断推注较持续输注在剖宫产脊麻中血压控制更精确,但组间差异小且未伴随临床结局差异。
主要发现
- 两组心输出量、恶心呕吐及新生儿结局无差异。
临床怎么用
- 间断推注可作为闭环血管升压药系统设计的一种有用替代方案。
局限性
- 组间血压控制差异小,且未伴随临床结局差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We previously described the use of closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure (BP) during spinal anesthesia for cesarean delivery. In this study, we report a modified system in which phenylephrine is delivered by intermittent boluses rather than infusion. We hypothesized that the use of computer-controlled boluses would result in more precise control of BP compared with infusions. METHODS: Two hundred fourteen healthy patients having spinal anesthesia for elective cesarean delivery were randomized to have their systolic BP maintained by phenylephrine administered by computer-controlled continuous infusion or computer-controlled intermittent boluses. From induction of anesthesia until the time of uterine incision, a noninvasive BP monitor was set to cycle at 1-minute intervals. In the infusion group, the infusion rate was automatically adjusted after each BP measurement using a previously described algorithm. In the bolus group, the algorithm was modified so that the mass of drug that would have been delivered over 1 minute was instead injected as a rapid intravenous bolus after each BP measurement. The precision of BP control was assessed using performance error calculations and compared between groups, with the primary outcome defined as median absolute performance error, and the latter being a measure of inaccuracy showing an average of the magnitudes of the differences of measured BP values above or below the target values. RESULTS: The precision of BP control was greater, as shown by smaller values for median absolute performance error, in the bolus group (median 4.38 [quartiles 3.22, 6.25] %) versus the infusion group (5.39 [4.12, 7.04] %, P = .008). In the bolus group, phenylephrine consumption was smaller; this was associated with smaller values for median performance error compared with the continuous infusion group (P < .001), which indicates that values for systolic BP, averaged over time, were slightly lower in the bolus group. There were no differences in cardiac output, nausea or vomiting, or neonatal outcome between groups. CONCLUSIONS: We confirmed the hypothesis that BP control was more precise when computer-controlled phenylephrine was delivered using intermittent boluses rather than continuous infusion. However, the difference between groups was small and was not associated with any difference in clinical outcomes. In the infusion group, greater doses of phenylephrine were delivered, which was related to the time taken for the noninvasive BP monitor to complete measurements. The use of intermittent boluses may be a useful alternative in the design of closed-loop vasopressor systems.
引用
- Ngan Kee WD, Tam YH, Khaw KS, et al. Closed-Loop Feedback Computer-Controlled Phenylephrine for Maintenance of Blood Pressure During Spinal Anesthesia for Cesarean Delivery: A Randomized Trial Comparing Automated Boluses Versus Infusion. Anesth Analg. 2017. PMID: 28368936. doi:10.1213/ANE.0000000000001974
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。