文献速递气道管理

气管导管套囊形状对术后咽痛的影响

Effect of Endotracheal Tube Cuff Shape on Postoperative Sore Throat After Endotracheal Intubation.
PubMed 文献 · Anesth Analg · 2017-01-01

BACKGROUND: Although minor, a sore throat after endotracheal intubation can adversely affect patient satisfaction and postoperative function. We compared the effects of 2 endotracheal tube cuff shapes on postoperative sore throat.…

要点

  • 锥形套囊导管可降低术后24小时咽痛累积发生率(32% vs 54%)。
  • 锥形套囊组术后6小时咽痛发生率和严重程度均低于圆柱形套囊组。

核心结论

  • 使用锥形套囊气管导管插管可降低术后咽痛的发生率和严重程度,并减少术后声嘶发生率。

临床怎么用

  • 在成人全麻气管插管时可优先选用锥形套囊导管,以减少术后咽痛和声嘶。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Although minor, a sore throat after endotracheal intubation can adversely affect patient satisfaction and postoperative function. We compared the effects of 2 endotracheal tube cuff shapes on postoperative sore throat. METHODS: One hundred ninety-one adult patients were included in the study. After induction of anesthesia, patients were randomized to endotracheal intubation with a conventional cylindrical-shaped cuff (Group C, n = 95) or a tapered-shaped cuff (Group T, n = 96). The number of intubation attempts, time to achieve endotracheal intubation, and duration of intubation were recorded. Postoperative sore throat and hoarseness were assessed at 1, 6, and 24 hours after surgery. A 0- to 100-mm visual analog scale was used to evaluate sore throat severity. The primary outcome of this study was the overall cumulative incidence of postoperative sore throat in the 24-hour evaluation period in the 2 groups. RESULTS: The overall incidence of postoperative sore throat was lower in Group T than in Group C (32% vs 54%; relative risk = 0.60, 95% confidence interval: 0.43-0.85; P= .003). At 6 hours after surgery, the incidence and severity of postoperative sore throat were lower in Group T compared with Group C (Bonferroni-corrected P< .05). Postoperative hoarseness also occurred less frequently in Group T compared with Group C (19% vs 37%; P= .006). Group T had lower incidence of hoarseness at 1 and 6 hours after surgery than Group C (Bonferroni-corrected P< .05), but the incidence of hoarseness at 24 hours after surgery did not differ between groups. CONCLUSIONS: Intubation using an endotracheal tube with a tapered cuff reduced the incidence and severity of postoperative sore throat and the incidence of hoarseness after surgery when compared with an endotracheal tube with a cylindrical cuff.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Chang JE, Kim H, Han SH, et al. Effect of Endotracheal Tube Cuff Shape on Postoperative Sore Throat After Endotracheal Intubation. Anesth Analg. 2017. PMID: 28368938. doi:10.1213/ANE.0000000000001933

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。