文献速递气道管理术前评估与围术期医学

超声测量舌厚度预测困难气管插管

Can tongue thickness measured by ultrasonography predict difficult tracheal intubation?
PubMed 文献 · Br J Anaesth · 2017-01-01

本研究纳入2254例全麻气管插管成人患者,术前用颏下超声正中矢状面测量舌厚度并计算舌厚度与甲颏距离比值。结果显示舌厚度>6.1 cm是困难插管的独立预测因素,联合比值>0.87时AUC达0.86。

要点

  • 舌厚度>6.1 cm预测困难插管的敏感度0.75、特异度0.72。
  • 舌厚度/甲颏距离比值>0.87时AUC 0.86,敏感度0.84、特异度0.79。
  • 颏下超声测量舌厚度可作为术前困难气道评估的辅助手段。

核心结论

  • 超声测量的舌厚度及其与甲颏距离的比值对困难气管插管具有显著预测能力。

研究设计与样本

  • 研究纳入2254例接受气管插管和全身麻醉的成人患者,术前用颏下超声正中矢状面测量舌厚度并进行气道评估,计算舌厚度与甲颏距离比值,主要结局为困难气管插管,采用多因素logistic回归和ROC曲线分析。

主要发现

  • 舌厚度>6.1 cm是困难气管插管的独立预测因素,敏感度0.75(95%CI 0.60-0.86),特异度0.72(95%CI 0.70-0.74)。
  • 舌厚度预测困难气管插管的AUC为0.78(95%CI 0.77-0.80)。
  • 舌厚度与甲颏距离比值>0.87时,AUC为0.86(95%CI 0.84-0.87),敏感度0.84(95%CI 0.71-0.93),特异度0.79(95%CI 0.77-0.81)。

临床怎么用

  • 术前可考虑用颏下超声测量舌厚度并计算其与甲颏距离比值,辅助识别困难气管插管高风险患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND.: Increased tongue thickness is likely to be associated with difficult airways. However, no methods to evaluate tongue thickness were available. Currently, tongue thickness can be measured by ultrasonography. The present study investigated the predictive value of tongue thickness to predict difficult tracheal intubation. METHODS.: Adult patients undergoing tracheal intubation and general anaesthesia were enrolled in the study. Tongue thickness was assessed using submental ultrasonography in the median sagittal plane before anaesthesia. Airway assessments were conducted. Ratios of tongue thickness to thyromental distance were calculated to investigate the potential predictive value of their combination. The primary outcome was difficult tracheal intubation. A multivariable logistic regression and receiver operating characteristic curve analysis were used. RESULTS.: In total, 2254 patients were analysed. One hundred and forty-two (6.3%) patients experienced difficult laryngoscopy, and 51 (2.3%) patients experienced difficult tracheal intubation. Increased tongue thickness (>6.1 cm) was an independent predictor for difficult tracheal intubation [sensitivity 0.75, 95% confidence interval (CI) 0.60-0.86; specificity 0.72, 95% CI 0.70-0.74]. An area under the curve of 0.78 (95% CI 0.77-0.80) for predicting difficult tracheal intubation was calculated. Increased ratios of tongue thickness to thyromental distance (>0.87) presented a considerable area under the curve (0.86, 95% CI 0.84-0.87), sensitivity (0.84, 95% CI 0.71-0.93), and specificity (0.79, 95% CI 0.77-0.81). CONCLUSIONS.: Tongue thickness measured by ultrasonography and its ratio to thyromental distance present significant capacities to predict difficult tracheal intubation. CLINICAL TRIAL REGISTRATION.: ChiCTR-RCS-14004539.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Yao W, Wang B. Can tongue thickness measured by ultrasonography predict difficult tracheal intubation? Br J Anaesth. 2017. PMID: 28403413. doi:10.1093/bja/aex051

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。