喉镜辅助光棒插管减少颈椎固定患者上颈椎运动
这项随机交叉研究在20例模拟颈椎固定的患者中比较了喉镜辅助光棒插管(LALI)与常规光棒插管(CLI)对插管期间颈椎运动的影响。结果显示LALI在枕骨-C1节段的颈椎运动小于CLI,差异有统计学意义,其他节段无显著差异。
要点
- LALI在枕骨-C1节段的运动为5.6°,小于CLI的9.3°。
- LALI与CLI在C1-C2和C2-C5节段的运动无显著差异。
- 模拟颈椎固定患者中,LALI可减少上颈椎运动。
核心结论
- 在模拟颈椎固定的患者中,LALI技术插管时上颈椎运动小于CLI技术。
研究设计与样本
- 随机交叉研究,纳入20例模拟颈椎固定的患者,分别接受LALI和CLI两种插管技术。
- 在枕骨-C1、C1-C2和C2-C5节段测量插管前和插管期间的颈椎角度。
关键数值与推荐
- 颈椎运动定义为插管期间各颈椎节段角度相对于基线的变化。
- LALI在枕骨-C1节段的运动为5.6°(4.3),CLI为9.3°(4.5)。
临床怎么用
- 对于模拟颈椎固定的患者,可考虑使用喉镜辅助光棒插管以减少上颈椎运动。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In patients with cervical immobilization, jaw thrust can cause cervical spine movement. Concurrent use of a laryngoscope may facilitate lightwand intubation, allowing midline placement and free movement of the lightwand in the oral cavity without jaw thrust. We compared the effects of laryngoscope-assisted lightwand intubation (LALI) versus conventional lightwand intubation (CLI) on cervical spine motion during intubation in patients with simulated cervical immobilization. METHODS: In this randomized crossover study, the cervical spine angle was measured before and during intubation at the occiput-C1, C1-C2, and C2-C5 segments in 20 patients with simulated cervical immobilization who underwent intubation using both the LALI and CLI techniques. Cervical spine motion was defined as the change from baseline in angle measured at each cervical segment during intubation. RESULTS: Cervical spine motion at the occiput-C1 segment was 5.6° (4.3) and 9.3° (4.5) when we used the LALI and CLI techniques, respectively (mean difference [98.33% CI]; -3.8° [-7.2 to -0.3]; P = .007). At other cervical segments, it was not significantly different between the 2 techniques (-0.1° [-2.6 to 2.5]; P = .911 in the C1-C2 segment and -0.2° [-2.8 to 2.5]; P = .795 in the C2-C5 segment). CONCLUSIONS: The LALI technique produces less upper cervical spine motion during intubation than the CLI technique in patients with simulated cervical immobilization.
引用
- Kim TK, Son JD, Seo H, et al. A Randomized Crossover Study Comparing Cervical Spine Motion During Intubation Between Two Lightwand Intubation Techniques in Patients With Simulated Cervical Immobilization: Laryngoscope-Assisted Versus Conventional Lightwand Intubation. Anesth Analg. 2017. PMID: 28244946. doi:10.1213/ANE.0000000000001813
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。