院前环境下预氧合策略的前瞻性随机试验
该前瞻性随机交叉研究在30名健康志愿者中比较了非再呼吸面罩、球囊面罩和便携呼吸机三种3分钟潮气量呼吸预氧合策略。主要结局为每种技术后首次呼气末氧浓度分数,非再呼吸面罩为64%(95%CI 60-68%),球囊面罩为89%(95%CI 86-92%),便携呼吸机为95%(95%CI 94-96%)。球囊面罩和便携呼吸机的预氧合效果显著优于非再呼吸面罩(p<0.001),但非再呼吸面罩的呼吸容易度显著更高。
要点
- 在健康志愿者中,球囊面罩和便携呼吸机的预氧合效果优于非再呼吸面罩。
- 非再呼吸面罩的呼气末氧浓度分数平均为64%,显著低于球囊面罩的89%和便携呼吸机的95%。
- 非再呼吸面罩的呼吸容易度显著高于球囊面罩和便携呼吸机。
核心结论
- 在健康志愿者中,球囊面罩和便携呼吸机的预氧合效果优于非再呼吸面罩。
研究设计与样本
- 前瞻性随机交叉研究,纳入30名健康志愿者,分别接受3分钟潮气量呼吸预氧合,使用非再呼吸面罩、球囊面罩和便携呼吸机。
主要发现
- 非再呼吸面罩的首次呼气末氧浓度分数均值为64%(95%CI 60-68%),球囊面罩为89%(95%CI 86-92%),便携呼吸机为95%(95%CI 94-96%)。
- 非再呼吸面罩的预氧合效果显著差于球囊面罩(p < 0.001)和便携呼吸机(p < 0.001)。
- 球囊面罩与便携呼吸机之间的呼吸容易度无显著差异,但两者均被感知为显著比非再呼吸面罩更难呼吸。
临床怎么用
- 在院前环境进行预氧合时,若条件允许,应优先选择球囊面罩或便携呼吸机而非非再呼吸面罩,以提高预氧合效果。
- 需权衡预氧合效果与呼吸容易度,非再呼吸面罩虽然效果较差但呼吸更容易。
局限性
- 研究仅在健康志愿者中进行,结果可能不直接适用于患者。
- 研究未报告其他预氧合策略或临床结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Pre-oxygenation before tracheal intubation aims to increase safe apnoea duration by denitrogenation of the functional residual capacity of the lungs, and increasing oxygen stores at the onset of apnoea. Pre-oxygenation options in the pre-hospital environment are limited due to oxygen availability and equipment portability. The aim of this study was to evaluate the effectiveness of strategies available in this setting. This was a prospective, randomised, crossover study of 30 healthy volunteers who underwent 3-min periods of pre-oxygenation by tidal volume breathing with a non-rebreather mask, a bag-valve-mask and a portable ventilator. The primary outcome measure was fractional expired oxygen concentration of the first exhaled breath after each technique. The secondary outcome measure was ease of breathing, assessed using a visual analogue scale. The mean (95%CI) fractional expired oxygen concentrations achieved with the non-rebreather mask were 64 (60-68)%, bag-valve-mask 89 (86-92)% and portable ventilator 95 (94-96)%. Pre-oxygenation efficacy with the non-rebreather mask was significantly worse than with either the bag-valve-mask (p < 0.001) or ventilator (p < 0.001). No significant difference in ease of breathing was identified between the bag-valve-mask and ventilator, but both were perceived as being significantly more difficult to breathe through than the non-rebreather mask. We conclude that, in healthy volunteers, the effectiveness of pre-oxygenation by bag-valve-mask and portable ventilator was superior to pre-oxygenation with a non-rebreather mask, although the non-rebreather mask was easier to breathe through than the other pre-oxygenation devices.
引用
- Groombridge CJ, Ley E, Miller M, et al. A prospective, randomised trial of pre-oxygenation strategies available in the pre-hospital environment. Anaesthesia. 2017. PMID: 28295147. doi:10.1111/anae.13852
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。