七氟烷致脑电等电位与爆发抑制:氧化亚氮的差异拮抗效应
本研究为前瞻性随机双盲平行组上下序贯分配试验,纳入77例ASA 1-2级患者,比较七氟烷复合60%氧化亚氮与对照组的ED50isoelectric和ED50burst。结果显示氧化亚氮组ED50isoelectric显著高于对照组,而两组ED50burst无显著差异。
要点
- 60%氧化亚氮可升高七氟烷致脑电等电位的ED50,但不影响爆发抑制的ED50。
- 氧化亚氮与七氟烷在脑电等电位终点上不呈预期相加效应,机制待探讨。
核心结论
- 加入60%氧化亚氮升高七氟烷的ED50isoelectric,但不改变ED50burst,提示两药在等电位终点上并非简单相加。
研究设计与样本
- 前瞻性随机双盲平行组上下序贯分配研究,共纳入77例ASA 1-2级患者。
主要发现
- 氧化亚氮组ED50isoelectric为4.08%(95%CI 3.95-4.38%),显著高于对照组的3.68%(95%CI 3.50-3.78%),p<0.0001。
- 氧化亚氮组ED50burst为3.05%(95%CI 2.66-3.90%),对照组为3.02%(95%CI 3.00-3.05%),p=0.52。
关键数值与推荐
- 脑电等电位定义为爆发抑制比100%持续>1分钟。
- 七氟烷起始浓度为2.5%,步长0.2%呼气末浓度。
临床怎么用
- 临床解读七氟烷脑电效应时需考虑复合氧化亚氮对等电位终点的拮抗影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The objective of this study was to investigate whether nitrous oxide influenced the ED50 of sevoflurane for induction of isoelectric electroencephalogram (ED50isoelectric ) differently from its influence on the ED50 of sevoflurane for electroencephalogram burst suppression (ED50burst ). In a prospective, randomised, double-blind, parallel group, up-down sequential allocation study, 77 ASA physical status 1 and 2 patients received sevoflurane induction and, after tracheal intubation, were randomly allocated to receive sevoflurane with either 40% oxygen in air (control group) or 60% nitrous oxide in oxygen mixture (nitrous group). The ED50isoelectric in the two groups was determined using Dixon's up and down method, starting at 2.5% with 0.2% step size of end-tidal sevoflurane. The electroencephalogram was considered as isoelectric when a burst suppression ratio of 100% lasted > 1 min. The subsequent concentrations of sevoflurane administered were determined by the presence or absence of isoelectric electroencephalogram in the previous patient in the same group. The ED50isoelectric in the nitrous group 4.08 (95%CI, 3.95-4.38)% was significantly higher than that in the control group 3.68 (95%CI, 3.50-3.78)% (p < 0.0001). The values for ED50burst were 3.05 (95%CI, 2.66-3.90)% and 3.02 (95%CI, 3.00-3.05)% in nitrous group and control group, respectively (p = 0.52). The addition of 60% nitrous oxide increases ED50isoelectric , but not the ED50burst of sevoflurane. Neither result indicates an additive effect of anaesthetic agents, as might be expected, and possible reasons for this are discussed.
引用
- Niu B, Xiao JY, Fang Y, et al. Sevoflurane-induced isoelectric EEG and burst suppression: differential and antagonistic effect of added nitrous oxide. Anaesthesia. 2017. PMID: 28272748. doi:10.1111/anae.13843
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。