文献速递心胸血管麻醉

心脏手术中红细胞输血相关溶血:观察性队列研究

Red Cell Transfusion-Associated Hemolysis in Cardiac Surgery: An Observational Cohort Study.
PubMed 文献 · Anesth Analg · 2017-01-01

该研究在543例体外循环心脏手术患者中,于转机后15-30分钟检测溶血指标,发现输血与游离血红蛋白无关,但与转铁蛋白饱和度独立相关,输血患者高转铁蛋白饱和度(>66%)的风险调整OR为6.2(95%CI 2.4-16.1)。

要点

  • 心脏手术输血后溶血可导致急性铁过载,转铁蛋白饱和度升高。
  • 输血与游离血红蛋白无关,但与转铁蛋白饱和度独立相关。
  • 避免或减轻输血相关急性铁过载可能提高输血安全性。

核心结论

  • 输血相关不良事件可能部分由输注红细胞过度溶血引起,导致急性铁过载及相关毒性。

研究设计与样本

  • 连续纳入543例体外循环心脏手术患者,于转机后15-30分钟检测溶血指标,采用多因素回归分析。

主要发现

  • 82例(15.1%)在转机期间接受红细胞输血,中位数1单位(IQR 1-2)。
  • 所有患者均可检测到游离血红蛋白,均值11.3±9.3 μmol/L,第90百分位18 μmol/L。
  • 转铁蛋白饱和度均值41±19%,第90百分位66%。
  • 控制混杂因素后,输血与游离血红蛋白无关(线性和逻辑回归P>.25),但与转铁蛋白饱和度直接相关(P<.001)。
  • 输血患者高转铁蛋白饱和度(>66%)的风险调整OR为6.2(95%CI 2.4-16.1)。

临床怎么用

  • 心脏手术输血时应关注溶血及铁过载风险,考虑避免或减轻输血相关急性铁过载的策略。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Red cell viability is impaired during storage, resulting in excess hemolysis during storage and after transfusion. As a result, transfusions may oversaturate the hemoglobin clearance pathways, resulting in cell-free hemoglobin and iron toxicity in susceptible patients, such as those undergoing cardiac surgery with cardiopulmonary bypass. To explore this hypothesis, we assessed the relationship of red cell transfusions with cell-free hemoglobin and transferrin saturation levels in a consecutive cohort of cardiac surgical patients. METHODS: Laboratory measures of hemolysis were obtained in consecutive cardiac surgical patients 15 to 30 minutes after bypass. Multivariable regression models controlling for important confounders were constructed to determine the independent relationship of red cell transfusions during bypass with cell-free hemoglobin and transferrin saturation levels post-bypass, analyzed as continuous variables (linear regression) and categorized at the 90th percentiles (logistic regression). RESULTS: Of the 543 included patients, 82 (15.1%) received red cell transfusions during bypass (median 1; interquartile range 1-2 units). Cell-free hemoglobin was detected in all patients (mean 11.3; standard deviation ± 9.3; 90th percentile 18 μmol/L), and transferrin saturations were relatively high (mean 41 ± 19%; 90th percentile 66%). After controlling for confounders, transfusions were not associated with cell-free hemoglobin (P > .25 in linear and logistic regression) but were directly associated with transferrin saturation levels (P < .001 in linear and logistic regression). Transfused patients had a 6.2-fold (95% confidence interval: 2.4-16.1) risk-adjusted increase in the odds of having high (>66%) transferrin saturation levels. CONCLUSIONS: The findings support the hypothesis that transfusion-related adverse events may be in part caused by the excessive hemolysis of transfused red cells, which can lead to acute iron overload and related toxicity. This suggests that strategies aimed at avoiding or mitigating transfusion-related acute iron overload may improve the safety of red cell transfusions.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Karkouti K, Callum JL, Acker JP, et al. Red Cell Transfusion-Associated Hemolysis in Cardiac Surgery: An Observational Cohort Study. Anesth Analg. 2017. PMID: 28221198. doi:10.1213/ANE.0000000000001807

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。