固定技术对连续肌间沟臂丛神经阻滞导管成功的影响:一项随机双盲试验

The Effect of Fixation Technique on Continuous Interscalene Nerve Block Catheter Success: A Randomized, Double-Blind Trial.
PubMed 文献 · Anesth Analg · 2017-01-01

本研究比较两种透明敷料下粘合剂(Dermabond与Mastisol)固定连续肌间沟神经阻滞导管的效果。主要结局为术后48小时导管尖端与神经对位维持情况。结果显示Dermabond组在术后第2天对位维持率显著高于Mastisol组(90.6% vs 64.7%),且Mastisol组导管漏液和移位更明显。

要点

  • Dermabond固定较Mastisol显著提高术后第2天导管尖端-神经对位维持率。
  • Mastisol组导管漏液和皮肤插入点移位显著多于Dermabond组。
  • 两组术后阿片类药物消耗量无显著差异。

核心结论

  • 在连续肌间沟神经阻滞中,使用Dermabond固定导管比Mastisol能更好地维持导管尖端与神经的对位。

临床怎么用

  • 对于连续肌间沟神经阻滞,可优先选择Dermabond固定导管以减少对位丧失、漏液和移位。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Continuous peripheral nerve blocks offer advantages over single-injection blocks, including extended analgesia and reduction in opioid consumption. These benefits require that the perineural catheter remain intact for the duration of the planned local anesthetic infusion. Mechanical displacement of catheters, leaking, and consequent failure are known complications. The aim of this study was to evaluate continuous perineural catheter tip-to-nerve apposition in vivo over 48 hours comparing 2 different simple fixation strategies. METHODS: Subjects presenting for a continuous interscalene nerve block were randomized to perineural catheter fixation with 1 of 2 types of adhesive: Dermabond (2-octylcyanoacrylate) or Mastisol (alcohol 23A, gum mastic, storax, and methyl salicylate), covered with a simple transparent dressing. The primary outcome was the evaluation of catheter-to-nerve apposition maintenance over 48 hours via both a blinded ultrasound evaluation of local anesthetic distribution and a blinded clinical assessment. Secondary outcomes included leakage at the catheter site, pain scores, opioid consumption, catheter-to-skin migration at the insertion site, and patient satisfaction. RESULTS: Sixty-six subjects were recruited and randomized to compare adhesive group catheter tip-to-nerve apposition on postoperative day 2 (POD 2). Within the intention-to-treat cohort, a statistically significant decrease of perineural catheter tip-to-nerve apposition in the Mastisol group (64.7%) compared with the Dermabond group (90.6%) on POD 2 (odds ratios [OR] 0.19; 95% confidence interval [CI] 0.05-0.75; P = .012) was observed. Similar results were observed on POD 1 (OR 0.19; 95% CI 0.03-1.38; P = NS) and POD 2 (OR 0.14; 95% CI 0.02-0.97; P = .008) within the as-treated cohort. Catheter leakage (OR 67; 95% CI 7.3-589) and median catheter migration difference at the skin insertion site (2.0 cm; 95% CI 0.5-2.5) were also significantly greater in the Mastisol group than in the Dermabond group from POD 0 to POD 2 (P < .001). Median postoperative opioid consumption difference in morphine equivalents (3.2 mg; 95% CI - 9.0 to 14.2) was not significantly different between the Dermabond and the Mastisol groups through POD 2 (P = .542). CONCLUSIONS: Perineural catheter fixation with Dermabond in continuous interscalene nerve block improves maintenance of catheter-to-nerve apposition when compared with Mastisol.

来源:Anesth Analg,查看原文。版权归原作者所有。