俯卧位椎板间硬膜外类固醇注射中腰颈段硬膜外深度影像与临床测量的一致性评估

Assessing the Agreement Between Radiologic and Clinical Measurements of Lumbar and Cervical Epidural Depths in Patients Undergoing Prone Interlaminar Epidural Steroid Injection.
PubMed 文献 · Anesth Analg · 2017-01-01

这项回顾性图表综述分析了335例在门诊慢性疼痛诊所接受俯卧位椎板间硬膜外类固醇注射(ESI)的患者,比较术前MRI测量的皮肤至黄韧带前缘距离(LFD)或硬膜距离(DD)与术中阻力消失(LOR)时Tuohy针深度的一致性。结果显示,腰椎LFD与LOR深度的ICC为0.88(95%CI 0.85-0.91),颈椎为0.72(95%CI 0.64-0.79);腰椎DD与LOR深度的ICC为0.86(95%CI 0.82-0.89),颈椎为0.69(95%CI 0.60-0.77)。结论认为MRI测量至黄韧带前缘与LOR深度的一致性优于测量至硬膜,但需进一步分析优化后方可支持临床应用。

要点

  • 腰椎LFD与LOR深度一致性ICC为0.88,颈椎为0.72。
  • 腰椎DD与LOR深度一致性ICC为0.86,颈椎为0.69。
  • MRI测量至黄韧带前缘与LOR深度一致性优于至硬膜。

核心结论

  • MRI测量皮肤至黄韧带前缘与LOR深度的一致性优于测量至硬膜或硬膜外间隙最前缘。
  • 研究结果需进一步分析和优化后方可支持临床应用。

研究设计与样本

  • 回顾性图表综述,分析2013年6月1日至2015年6月1日间在门诊慢性疼痛诊所接受俯卧位椎板间ESI的患者。
  • 共纳入335例ESI,其中颈椎147例,腰椎188例。
  • 收集BMI、年龄、性别、ESI椎间隙水平和LOR深度,并在MRI上测量皮肤至黄韧带前缘距离(LFD)和至硬膜距离(DD)。
  • 按年龄≥65岁、<65岁、BMI≥30 kg/m²(肥胖)、BMI<30 kg/m²(非肥胖)、男性和女性进行亚组分析。
  • 使用组内相关系数(ICC)和Bland-Altman图评估DD或LFD与LOR深度的一致性。

主要发现

  • 腰椎LOR深度与LFD的ICC为0.88(95%CI 0.85-0.91),颈椎为0.72(95%CI 0.64-0.79)。
  • 腰椎LOR深度与DD的ICC为0.86(95%CI 0.82-0.89),颈椎为0.69(95%CI 0.60-0.77)。

临床怎么用

  • 术前MRI测量皮肤至黄韧带前缘距离可能有助于预估俯卧位椎板间ESI的针深度。
  • 颈椎ESI的影像与临床深度一致性低于腰椎,需谨慎解读。

局限性

  • 研究为回顾性设计。
  • 结果需进一步分析和优化后方可支持临床应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Fluoroscopy-guided epidural steroid injection (ESI) commonly is performed to treat radicular pain yet can lead to adverse events if the needle is not advanced with precision. Accurate preoperative assessment of the distance from the skin to the epidural space holds the potential for reducing the risks of adverse effects from ESI. It was hypothesized that the distance from the skin to the epidural space as measured on preoperative magnetic resonance imaging (MRI) would agree with the distance traveled by a Tuohy needle to reach the epidural space during midline, interlaminar ESI. This study compared the final needle depth measurement at the point of loss of resistance (LOR) from cervical or lumbar ESI to the distance from the skin to the anterior and posterior borders of the epidural space on the associated cervical and lumbar preoperative MRI. METHODS: This retrospective chart review analyzed the procedure notes, MRI, and demographic data of patients who received a prone, interlaminar ESI at an outpatient chronic pain clinic between June 1, 2013, and June 1, 2015. The following data were collected: body mass index (BMI), age, sex, intervertebral level of the ESI, and LOR depth. We then measured the distance from the skin surface to the anterior border of the ligamentum flavum (ligamentum flavum depth [LFD]) and dura (dura depth [DD]) on MRI. A total of 335 patients were categorized into the following patient subgroups: age ≥65 years, age <65 years, BMI ≥30 kg/m (obese), BMI <30 kg/m (nonobese), male, and female. Secondary analyses were then performed to compare the agreement between LOR depth and DD with that between LOR depth and LFD within each patient subgroup. Intraclass correlation coefficient (ICC) and Bland-Altman plot were used to assess the agreement between DD or LFD and LOR depth. RESULTS: Data from 335 ESIs were analyzed, including 147 cervical ESIs and 188 lumbar ESIs. Estimated ICC values for the agreement between LOR depth and LFD for all lumbar and cervical measurements were 0.88 (95% confidence interval [CI], 0.85-0.91) and 0.72 (95% CI, 0.64-0.79), respectively. Estimated ICC values for the agreement between LOR depth and DD for all lumbar and cervical measurements were 0.86 (95% CI, 0.82-0.89) and 0.69 (95% CI, 0.60-0.77), respectively. CONCLUSIONS: This study assessed the agreement between MRI-derived measurements of epidural depth and those determined clinically. MRI-derived measurements from the skin to the anterior border of the ligamentum flavum, which represents the most posterior aspect of the epidural space, revealed stronger agreement with LOR depths than did measurements to the dura or the most anterior aspect of the epidural space. These results require further analysis and refinement before supporting clinical application.