文献速递区域麻醉与超声

融合弹性成像与B超可提高麻醉学员对神经内注射的诊断准确性

Trainee anaesthetist diagnosis of intraneural injection-a study comparing B-mode ultrasound with the fusion of B-mode and elastography in the soft embalmed Thiel cadaver model.
PubMed 文献 · Br J Anaesth · 2016-01-01

该研究利用软防腐Thiel尸体模型,记录40例正中神经阻滞视频,比较B超与B超联合弹性成像融合图像对20名麻醉学员诊断神经内注射的影响。结果显示融合弹性成像的诊断比值比(DOR)为21.7(95%CI 14.5-33.3),显著高于B超的7.4(95%CI 5.2-10.6),且学员诊断信心和可靠性均提高。

要点

  • 融合弹性成像可显著提高麻醉学员诊断神经内注射的准确性。
  • 神经内注射在融合弹性成像上表现为明亮半透明图像,几何比0.33。
  • 融合弹性成像还能提升诊断信心和评分者间可靠性。

核心结论

  • 融合弹性成像提高了麻醉学员诊断神经内注射的准确性、可靠性和信心。

研究设计与样本

  • 在软防腐Thiel尸体模型上记录40例正中神经阻滞,随机分配0.25 ml、0.5 ml、1 ml容量至五个注射位点。
  • 20名麻醉学员分别观看B超视频、B超与弹性成像相邻视频、融合弹性成像视频或重复B超视频,判断注射为神经内或神经外。

主要发现

  • 融合弹性成像诊断神经内注射的DOR(95%CI)为21.7(14.5-33.3),B超为7.4(5.2-10.6),P < 0.001。
  • 与神经外注射相比,神经内注射在融合弹性成像上表现为 distinct、更明亮的半透明图像,几何比0.33(95%CI 0.16-0.49),P < 0.001。
  • 融合弹性成像与学员诊断信心提高相关,OR(95%CI)为1.89(1.69-2.11),P < 0.001。
  • 融合弹性成像的可靠性Kappa(95%CI)为0.60(0.55-0.66)。

临床怎么用

  • 在超声引导区域麻醉培训中,可考虑将弹性成像与B超融合用于辅助学员识别神经内注射。

局限性

  • 研究在软防腐Thiel尸体模型中进行,结果外推至活体临床实践需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The incidence of intraneural injection during trainee anaesthetist ultrasound guided nerve block varies between 16% in experts and up to 35% in trainees. We hypothesized that elastography, an ultrasound-based technology that presents colour images of tissue strain, had the potential to improve trainee diagnosis of intraneural injection during UGRA, when integrated with B-Mode ultrasound onto a single image. METHODS: We recorded 40 median nerve blocks randomly allocated to 0.25 ml, 0.5 ml, 1 ml volumes to five sites, on both arms of two soft embalmed cadavers, using a dedicated B-Mode ultrasound and elastography transducer. We wrote software to fuse elastogram and B-Mode videos, then asked 20 trainee anaesthetists whether injection was intraneural or extraneural when seeing B-Mode videos, adjacent B-Mode and elastogram videos, fusion elastography videos or repeated B-Mode ultrasound videos. RESULTS: Fusion elastography improved the diagnosis of intraneural injection compared with B-Mode ultrasound, Diagnostic Odds Ratio (DOR) (95%CI) 21.7 (14.5 - 33.3) vs DOR 7.4 (5.2 - 10.6), P < 0.001. Compared with extraneural injection, intraneural injection was identified on fusion elastography as a distinct, brighter translucent image, geometric ratio 0.33 (95%CI: 0.16 - 0.49) P < 0.001. Fusion elastography was associated with greater trainee diagnostic confidence, OR (95%CI) 1.89 (1.69 - 2.11), P < 0.001, and an improvement in reliability, Kappa 0.60 (0.55 - 0.66). CONCLUSIONS: Fusion elastography improved the accuracy, reliability and confidence of trainee anaesthetist diagnosis of intraneural injection.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Munirama S, Zealley K, Schwab A, et al. Trainee anaesthetist diagnosis of intraneural injection-a study comparing B-mode ultrasound with the fusion of B-mode and elastography in the soft embalmed Thiel cadaver model. Br J Anaesth. 2016. PMID: 27956678

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。