文献速递疼痛医学

癌症相关疼痛鞘内泵导管迁移率研究

Implanted intrathecal pump catheter migration rates in the management of cancer-related pain.
PubMed 文献 · Reg Anesth Pain Med · 2026-09-08

两次CT扫描间导管迁移发生率为15.4%(18例),均为单一椎体水平;全队列中需翻修的影像学显著迁移仅2例(0.45%),无人口学或临床因素与迁移显著相关。

要点

  • 轻微导管迁移较常见,但临床显著迁移罕见。
  • 所描述的锚定和闭合技术下需翻修的迁移仅0.45%。
  • 未发现与导管迁移显著相关的人口学或临床因素。

核心结论

  • 鞘内泵植入后轻微导管迁移相对常见,但临床显著迁移罕见。

主要发现

  • 117例中15.4%(n=18)在两次CT间发生导管迁移,均限于单一椎体水平。
  • 全队列441例中,需翻修的影像学显著迁移仅2例(0.45%)。
  • 未发现任何人口学或临床因素与迁移显著相关。

关键数值与推荐

  • 导管迁移定义为两次影像学检查比较时导管移动一个或以上椎体水平。

临床怎么用

  • 采用所描述的锚定和闭合技术时,临床显著导管迁移罕见,但仍需关注轻微迁移。

局限性

  • 回顾性设计,仅117例符合影像学分析条件,可能低估迁移发生率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Intrathecal drug delivery systems offer a potent modality for managing cancer-related pain that is resistant to conservative measures. However, catheter-related complications, particularly migration, remain a concern. This study assessed the prevalence, risk factors, and implications of catheter migration rates in patients with intrathecal pumps (ITP) for cancer-related pain. MATERIALS AND METHODS: A retrospective database and chart review of 441 patients with cancer with an ITP at the Huntsman Cancer Institute from May 2014 to December 2023 was performed to identify patients who had two chest CT scans after implant separation by at least 30 days. Catheter migration was defined as movement of the catheter by one or more vertebral levels when comparing the two imaging studies. Demographics were analyzed to identify factors associated with migration. To identify subjects with catheter complications missed by the initial approach, an additional chart review was performed to identify operative procedures linked to catheter revision. RESULTS: 117 patients were suitable for analysis, and 15.4% (n=18) had catheter migration between the two CT scans. These were all limited to a single vertebral level. Across the full cohort of 441 patients, radiographically significant migration requiring revision occurred in only two patients (0.45%). No demographic or clinical factors were significantly associated with migration. CONCLUSIONS: Minor catheter migration is relatively common following ITP implantation, but clinically significant migration is rare with the anchoring and closure techniques described.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Martinez Alvarez GA, Brogan SE, Odell DW, et al. Implanted intrathecal pump catheter migration rates in the management of cancer-related pain. Reg Anesth Pain Med. 2026. PMID: 42710946. doi:10.1136/rapm-2025-106866

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。