文献速递小儿麻醉气道管理

声门上气道装置与气道高反应性患儿诱导期呼吸不良事件的关系:J-PEDIA登记研究

Association between supraglottic airway device use and respiratory adverse events during airway management in children with airway hyperresponsiveness: a report from the Japan Paediatric Difficult Airway in Anaesthesia (J-PEDIA) registry.
PubMed 文献 · Br J Anaesth · 2026-09-29

基于日本J-PEDIA多中心回顾性队列(12家机构,2022年7月至2025年2月),分析4878例气道高反应性患儿诱导期气道管理。经倾向评分逆概率加权调整后,声门上气道装置置入较气管插管与呼吸不良事件风险降低相关(aRR 0.41,95%CI 0.19-0.62,P<0.001)。

要点

  • 气道高反应性患儿诱导期使用声门上气道装置与呼吸不良事件风险降低相关。
  • 调整后aRR 0.41(95%CI 0.19-0.62,P<0.001),气道管理相关不良事件aRR 0.32。
  • 严重氧饱和度下降风险亦降低(aRR 0.47,95%CI 0.19-0.75,P<0.001)。

核心结论

  • 气道高反应性患儿诱导期使用声门上气道装置与呼吸不良事件风险降低相关。

研究设计与样本

  • 多中心回顾性队列研究,日本J-PEDIA登记,12家三级机构,2022年7月至2025年2月。
  • 纳入18岁以下、有活动性上呼吸道感染、14天内上呼吸道感染、哮喘急性发作或家庭吸烟暴露的全身麻醉患儿。
  • 共分析4878例,气管插管3005例(61.6%),声门上气道装置1873例(38.4%),采用倾向评分逆概率加权调整。

主要发现

  • 调整后声门上气道装置置入与呼吸不良事件风险降低相关(aRR 0.41;95%CI 0.19-0.62;P<0.001)。
  • 与气道管理相关不良事件风险降低相关(aRR 0.32;95%CI 0.19-0.45;P<0.001)。
  • 与严重氧饱和度下降风险降低相关(aRR 0.47;95%CI 0.19-0.75;P<0.001)。

临床怎么用

  • 临床合适时,可考虑对气道高反应性患儿诱导期使用声门上气道装置。
  • 需认识到观察性研究可能存在残余混杂。

局限性

  • 原文提及可能存在残余混杂。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Children with airway hyperresponsiveness face higher risks of perioperative respiratory adverse events. Although the use of supraglottic airway devices (SADs) is associated with fewer perioperative respiratory adverse events than tracheal intubation in selected paediatric populations, evidence remains limited regarding induction-phase airway management in children with airway hyperresponsiveness. We aimed to investigate the association between SAD placement (vs tracheal intubation) and respiratory adverse events during induction-phase airway management in children with airway hyperresponsiveness using propensity score-based inverse probability of treatment weighting. METHODS: This multicentre retrospective cohort study was conducted at 12 tertiary-care institutions (six paediatric and six mixed adult-paediatric university hospitals) in the Japan Paediatric Difficult Airway in Anaesthesia registry between July 2022 and February 2025. We included children aged <18 yr undergoing general anaesthesia who had an active upper respiratory tract infection, an upper respiratory tract infection within the preceding 14 days, asthma exacerbation, or household smoking exposure. The primary outcome was the occurrence of respiratory adverse events. RESULTS: Of the 27 844 encounters, 4878 were analysed (tracheal intubation 3005 of 4878 [61.6%]; SAD 1873 of 4878 [38.4%]). After adjustment, SAD placement was associated with a lower risk of respiratory adverse events (adjusted risk ratio [aRR] 0.41; 95% confidence interval [CI] 0.19-0.62; P<0.001), airway management-related adverse events (aRR 0.32; 95% CI 0.19-0.45; P<0.001), and severe oxygen desaturation (aRR 0.47; 95% CI 0.19-0.75; P<0.001). CONCLUSIONS: Overall, supraglottic airway device use during induction of anaesthesia was associated with a lower risk of adverse respiratory events in children with airway hyperresponsiveness. These findings support consideration of supraglottic airway devices when clinically appropriate while acknowledging potential residual confounding.

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Uchinami Y, Soejima T, Nishida S, et al. Association between supraglottic airway device use and respiratory adverse events during airway management in children with airway hyperresponsiveness: a report from the Japan Paediatric Difficult Airway in Anaesthesia (J-PEDIA) registry. Br J Anaesth. 2026. PMID: 42810867. doi:10.1016/j.bja.2026.07.046

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。