文献速递气道管理术前评估与围术期医学

坐位与仰卧位改良Mallampati试验预测困难气道的系统评价与Meta分析

Sitting Versus Supine Modified Mallampati Test for Predicting Difficult Airway: A Systematic Review and Meta-analysis.
PubMed 文献 · Anesth Analg · 2026-07-24

该系统评价与Meta分析纳入20项观察性研究共8261例患者,比较同一患者坐位与仰卧位改良Mallampati试验对困难喉镜暴露(Cormack-Lehane分级≥III)的诊断准确性。坐位汇总敏感度0.661、特异度0.783,仰卧位敏感度0.750、特异度0.705,SROC曲线明显重叠,Meta回归显示体位对敏感度或假阳性率均无统计学显著影响。结论认为诊断准确性不受体位显著影响,仰卧位可作为无法坐位评估时的替代选择。

要点

  • 坐位与仰卧位改良Mallampati试验预测困难气道的诊断准确性无显著差异。
  • 仰卧位评估可作为无法进行直立位评估时的替代方案,纳入多模式气道评估。
  • 两种体位的SROC曲线明显重叠,体位不是敏感度或假阳性率的显著协变量。

核心结论

  • 改良Mallampati试验预测困难气道的诊断准确性与患者体位无显著关联。
  • 当无法进行直立位评估时,仰卧位评估可作为多模式气道评估的替代选择。

研究设计与样本

  • 系统评价与Meta分析,纳入20项在同一患者中评估仰卧位与坐位改良Mallampati试验的观察性研究,共8261例患者。
  • 检索PubMed、Embase、Cochrane Database和Web of Science,检索时间从建库至2026年1月。
  • 主要结局为困难喉镜暴露的诊断准确性,定义为Cormack-Lehane分级≥III;采用双变量随机效应模型估计汇总敏感度和特异度。

主要发现

  • 坐位改良Mallampati试验汇总敏感度为0.661(95%CI 0.573-0.738),汇总特异度为0.783(95%CI 0.684-0.858)。
  • 仰卧位改良Mallampati试验汇总敏感度为0.750(95%CI 0.617-0.849),汇总特异度为0.705(95%CI 0.57-0.813)。
  • 汇总受试者工作特征曲线显示两种体位明显重叠。
  • Meta回归和似然比检验表明患者体位对敏感度或假阳性率均不是统计学显著的协变量。

关键数值与推荐

  • 困难喉镜暴露定义为Cormack-Lehane分级≥III。
  • 坐位敏感度0.661(95%CI 0.573-0.738)、特异度0.783(95%CI 0.684-0.858);仰卧位敏感度0.750(95%CI 0.617-0.849)、特异度0.705(95%CI 0.57-0.813)。

临床怎么用

  • 改良Mallampati试验可在仰卧位进行,尤其适用于无法坐位的患者。
  • 仰卧位评估结果可作为多模式气道评估的一部分,用于预测困难气道。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The modified Mallampati test is performed in the sitting position as part of airway evaluation to predict difficult airway. However, it is not feasible in patients unable to sit, and the accuracy in supine position remains unclear. This study compared the diagnostic performance of the modified Mallampati test between two positions. METHODS: We conducted a systematic review and meta-analysis of observational studies evaluating the modified Mallampati test in supine and sitting positions in the same patients. PubMed, Embase, Cochrane Database, and Web of Science were searched from inception to January 2026. The primary outcome was diagnostic accuracy of difficult laryngoscopy, defined as Cormack-Lehane grade ≥III. Pooled sensitivity and specificity were estimated using bivariate random-effects models. Meta-regression and likelihood ratio test were used to assess the effect of patient position. RESULTS: Twenty studies involving 8261 patients were included. Pooled sensitivity and specificity for the sitting position were 0.661 (95% confidence interval [CI], 0.573-0.738) and 0.783 (95% CI, 0.684-0.858), respectively, and those for the supine position were 0.750 (95% CI, 0.617-0.849) and 0.705 (95% CI, 0.57-0.813), respectively. Summary receiver operating characteristic curves indicated substantial overlap. Meta-regression and likelihood ratio test indicated that patient position was a nonstatistically significant covariate for sensitivity or the false-positive rate. CONCLUSIONS: The diagnostic accuracy of the modified Mallampati test for predicting difficult airway was not significantly associated with patient position. Supine assessment may be an alternative when upright assessment is not feasible as part of a multimodal airway assessment.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Vo BTN, Huynh YP, Tang PM, et al. Sitting Versus Supine Modified Mallampati Test for Predicting Difficult Airway: A Systematic Review and Meta-analysis. Anesth Analg. 2026. PMID: 42520296. doi:10.1213/ANE.0000000000008235

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。