呼气末正压降低后每搏输出量变化对单肺通气期间容量反应性的预测能力
单中心前瞻性干预研究纳入38例择期肺切除需单肺通气成人,评估PEEP试验诱导的每搏输出量变化(ΔSVPEEP test)预测容量反应性。ΔSVPEEP test的AUC为0.95,最佳截断值8.6%时敏感度94.4%、特异度80.0%;ΔMAPPEEP test的AUC为0.84,而SVV无预测价值。
要点
- 单肺通气期间,PEEP试验诱导的每搏输出量变化可预测容量反应性。
- ΔSVPEEP test最佳截断值8.6%,敏感度94.4%、特异度80.0%。
- 基线每搏输出量变异度(SVV)在单肺通气期间无预测价值。
核心结论
- 单肺通气期间,PEEP试验诱导的每搏输出量相对增加可预测以Trendelenburg体位为容量负荷试验定义的容量反应性。
研究设计与样本
- 单中心前瞻性干预研究,2024年6月至9月纳入38例择期肺切除需单肺通气的成人患者。
主要发现
- 38例中18例(47%)为容量反应者。
- 反应者ΔSVPEEP test为16.7% ± 8.9,非反应者为4.6% ± 4.3(P < .0001)。
- ΔSVPEEP test的AUC为0.95(95%CI 0.82-0.99;P < .0001),最佳截断值8.6%时敏感度94.4%(95%CI 72.7-99.9)、特异度80.0%(95%CI 56.3-94.3)。
- ΔMAPPEEP test的AUC为0.84(95%CI 0.68-0.94;P < .0001)。
- SVV无预测价值(AUC 0.64,95%CI 0.47-0.79;P = .12),ΔSVPEEP test灰区为3.6%至12.5%,涵盖14/38例(36.8%)。
临床怎么用
- 胸科麻醉单肺通气期间,可考虑用PEEP试验诱导的每搏输出量变化指导术中液体管理。
局限性
- 单中心小样本研究,结果需多中心验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: During one-lung ventilation (OLV) with low tidal volumes, asymmetric intrathoracic pressures may blunt the cardiopulmonary interactions on which conventional dynamic indices rely, limiting their usefulness for guiding fluid therapy. The positive end-expiratory pressure (PEEP) test, a reduction in PEEP to augment venous return, has been proposed as a fluid-free assessment of preload responsiveness in mechanically ventilated patients. However, whether its diagnostic performance is retained during OLV is unknown. We therefore hypothesized that the stroke-volume change (ΔSVPEEP test) induced by the PEEP test would predict fluid responsiveness during OLV. METHODS: We conducted a single-center prospective interventional study (June to September 2024) in adults undergoing elective lung resection requiring OLV. The primary objective was to evaluate the diagnostic accuracy of the ΔSVPEEP test for predicting fluid responsiveness. Secondary objectives were to assess the diagnostic performance of the PEEP test-induced change in mean arterial pressure (ΔMAPPEEP test) and baseline stroke volume variation (SVV), and to compare their predictive abilities. After stabilization using OLV (PEEP 10 cm H2O) but before skin incision (closed-chest conditions), baseline hemodynamics were recorded; stroke volume (SV) was measured by arterial pulse-contour analysis. PEEP was then reduced from 10 to 0 cm H2O, and variables were re-measured. Subsequently, a 15° head-down tilt (Trendelenburg) served as an autotransfusion challenge; patients with ≥10% SV increase were classified as responders. Receiver operating characteristic (ROC) analysis was used to assess the predictive ability of each index. A gray-zone analysis was performed for the ΔSVPEEP test to delineate the range of diagnostic uncertainty. RESULTS: Of 43 patients screened, 38 were analyzed; 18 (47%) were responders. ΔSVPEEP test was larger in responders than in nonresponders (16.7% ± 8.9 vs 4.6% ± 4.3; P < .0001). ΔSVPEEP test predicted fluid responsiveness with an area under the ROC curve (AUC) of 0.95 (95% confidence interval [CI], 0.82-0.99; P < .0001), and the optimal cutoff of 8.6% yielded 94.4% sensitivity (95% CI, 72.7-99.9) and 80.0% specificity (95% CI, 56.3-94.3). ΔMAPPEEP test showed an AUC of 0.84 (95% CI, 0.68-0.94; P < .0001), whereas SVV was not predictive (AUC 0.64, 95% CI, 0.47-0.79; P = .12). The gray zone for the ΔSVPEEP test was 3.6% to 12.5%, comprising 14 of 38 (36.8%) of patients. CONCLUSIONS: During OLV, the relative increase in SV elicited by the PEEP test predicted fluid responsiveness as defined by the Trendelenburg maneuver. This simple, fluid-free maneuver may assist intraoperative fluid management during thoracic anesthesia.
引用
- Takai M, Juri T, Tanimoto R, et al. Predictive Ability of Stroke Volume Changes Following Positive End-Expiratory Pressure Reduction on Fluid Responsiveness During One-Lung Ventilation. Anesth Analg. 2026. PMID: 42268782. doi:10.1213/ANE.0000000000008149
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。