可弯曲插管镜联合视频喉镜与单用可弯曲插管镜:一项前瞻性随机临床试验
该前瞻性随机试验纳入135例预期困难气道的成人择期手术患者,1:1随机分为单用可弯曲插管镜(FIS)组或FIS联合视频喉镜(FIS/VL)组。
要点
- 预期困难气道成人中,FIS联合VL未显著降低困难气管插管复合终点发生率。
核心结论
- 在预期困难气道的成人中,FIS联合VL未显著降低困难气管插管复合终点发生率,但与更少的重复尝试和更少的操作者评价困难/失败插管相关。
研究设计与样本
- 前瞻性随机临床试验,筛查144例,纳入135例预期困难气道的成人择期手术患者,1:1随机分为FIS/VL组66例和FIS组69例。
- 主要终点为困难气管插管复合终点,定义为首次插管时间>60秒、首次插管失败或操作者评价插管困难中任一项。
关键数值与推荐
- 困难气管插管复合终点定义:首次插管时间>60秒、首次插管失败或操作者评价插管困难。
- 操作者插管难易度采用5点Likert量表:1极度容易、2有些容易、3导管推进阻力归为不困难,4困难、5失败归为困难/失败。
临床怎么用
- 对预期困难气道成人,可考虑FIS联合VL的双可视化策略以改善首次插管成功率和操作者评价的插管难易度。
- 联合策略对困难气管插管复合终点的获益尚需更大规模试验确定。
局限性
- 主要复合终点组间差异无统计学意义,原文指出需要更大规模试验确定其对复合困难终点的影响。
- 135例随机患者中仅128例提供可分析的主要复合终点数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: In patients with anticipated difficult airways, suboptimal airway management may increase perioperative morbidity and mortality. Combining video laryngoscopy (VL) with a flexible intubation scope (FIS) has been shown to enhance visualization and facilitate endotracheal tube passage in patients with known or anticipated difficult airways. To date, randomized evidence supporting this approach remains limited. METHODS: In this prospective, randomized trial, 135 adults with anticipated difficult airways undergoing elective surgery were randomized 1:1 to intubation with FIS alone or a combined technique using FIS with VL (FIS/VL). The primary end point was the composite rate of difficult endotracheal tube (ETT) placement, defined by one or more of the following: (1) first-attempt intubation time >60 seconds; (2) failure to intubate on the first attempt; or (3) provider assessment of the intubation process as difficult. Provider-rated ease of intubation was recorded immediately following the procedure by the anesthesiologist performing the intubation using a 5-point Likert scale. Scores of 1 (extremely easy), 2 (somewhat easy), and 3 (resistance to tube advancement) were classified as Not Difficult, whereas scores of 4 (difficult) and 5 (unsuccessful) were classified as Difficult/Unsuccessful. For analysis and reporting, the Likert-scale ratings were dichotomized into a binary outcome (Not Difficult vs Difficult/Unsuccessful). The secondary outcome was total intubation time. RESULTS: A total of 144 patients were screened and enrolled, and 135 patients were randomized. Of these, 66 patients were assigned to the FIS/VL arm and 69 patients to the FIS arm. Among the 135 randomized patients, 128 provided analyzable data for the composite primary end point. Overall, the first-pass success rate was 54/58 (93.1%) in the FIS/VL group versus 50/64 (78.1%) in the FIS group; P = .020. Intubation time greater than 60 seconds was similar between groups (33/66 [52.4%] in the FIS arm vs 24/61 [39.3%] in the FIS/VL arm; P = .145). Provider-rated ease of intubation considered difficult or unsuccessful occurred in 4/64 (6.1%) of FIS/VL compared to 13/67 (19.4%) of FIS cases (P = .025). Among the 128 evaluable patients (61 FIS/VL, 67 FIS), the composite primary end point- difficult ETT placement defined as (1) first-attempt intubation time >60 seconds, (2) failure on first attempt at intubation, or (3) provider-rated difficult intubation occurred in 28/61 (45.9%) of FIS/VL versus 40/67 (59.7%) of FIS cases [Risk difference (95% CI) = -0.14 (-0.31 to 0.03); P = .118]. CONCLUSIONS: In adults with anticipated difficult airways, adding VL to FIS did not significantly reduce the composite rate of difficult ETT placement, although it was associated with fewer repeat attempts and fewer provider-rated difficult/unsuccessful intubations. These findings support the clinical value of dual-visualization strategies to improve first-pass performance metrics, whereas larger trials are needed to determine their effect on composite difficulty end points.
引用
- Williams UU, Owusu-Agyemang P, Vu CN, et al. Flexible Intubation Scope versus Flexible Intubation Scope and Video Laryngoscopy Combination: A Prospective Randomized Clinical Trial. Anesth Analg. 2026. PMID: 42233755. doi:10.1213/ANE.0000000000008133
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。