文献速递气道管理小儿麻醉

McGRATH MAC视频喉镜用于麻醉学员婴儿首次插管的随机对照试验

Effectiveness of McGRATH MAC Video Laryngoscopy for First-Attempt Intubation by Anesthesia Trainees in Infants: A Randomized Controlled Trial.
PubMed 文献 · Anesth Analg · 2026-02-16

单中心随机对照试验纳入124例<1岁择期手术婴儿,麻醉学员在监督下分别使用McGrath视频喉镜或直接喉镜插管。结论认为McGrath视频喉镜可提高麻醉学员婴儿首次插管成功率,支持新手常规使用。

要点

  • 麻醉学员使用McGrath视频喉镜婴儿首次插管成功率86.9%,高于直接喉镜74.6%。
  • McGrath组插管困难评分0分比例49.2%,直接喉镜组31.7%。
  • McGrath组声门开放百分比100%比例60.7%,直接喉镜组36.5%。

核心结论

  • McGrath视频喉镜显著提高麻醉学员婴儿首次插管成功率,尤其对经验较少者。
  • 视频喉镜可能提升婴儿气道管理的安全性与有效性,支持新手常规使用。

研究设计与样本

  • 单中心、平行组随机对照试验,纳入124例<1岁择期手术需经口气管插管的婴儿。
  • 随机分为McGrath视频喉镜组(n=61)和直接喉镜组(n=63),均由麻醉学员在监督下插管。

主要发现

  • 插管困难评分0分McGrath组30/61(49.2%),直接喉镜组20/63(31.7%),风险差18.9%(95%CI 0.6%-37.2%)。
  • 声门开放百分比100%McGrath组37/61(60.7%),直接喉镜组23/63(36.5%),风险差22.1%(95%CI 6.2%-37.9%)。
  • 插管相关并发症总发生率McGrath组5/61(8.2%),直接喉镜组7/63(11.1%),风险差-4.1%(95%CI -14.7%-6.4%)。
  • 食管插管McGrath组0/61(0%),直接喉镜组3/63(4.8%)。

临床怎么用

  • 麻醉学员对婴儿行气管插管时可优先选择McGrath视频喉镜以提高首次成功率。
  • 对经验较少的操作者,视频喉镜有助于改善声门视野和降低插管难度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Tracheal intubation in infants poses unique anatomical and physiological challenges and is particularly difficult for anesthesia trainees. Video laryngoscopy has been suggested to improve intubation success, yet evidence among novice providers remains limited. We aimed to evaluate whether anesthesia trainees had a higher first-attempt success rate for tracheal intubation in infants using traditional direct laryngoscopy (DL) with a Miller or Macintosh blade, or indirect video laryngoscopy with a McGrath video laryngoscope size 1 Macintosh blade (McGrath VL). METHODS: In this single-center, parallel-group, randomized controlled trial, infants (<1-year-old) scheduled for elective surgery requiring orotracheal intubation were randomly allocated to either McGrath VL or DL. All intubations were performed by anesthesia trainees under supervision. The primary outcome was the first-attempt intubation success rate. Secondary outcomes included intubation difficulty score, glottic visualization, time to intubation, and intubation-related complications. RESULTS: Between October 2021 and February 2024, 124 infants were enrolled and randomized (McGrath VL: n = 61; DL: n = 63). First-attempt success was achieved in 53/61 (86.9%) in the McGrath VL group and 47/63 (74.6%) in the DL group (risk difference 16.5%, 95% confidence interval [CI],3.0%-29.9%; P = .026). The Intubation Difficulty Score of 0 occurred in 30/61 (49.2%) in the McGrath VL group versus 20/63 (31.7%) in the DL group (risk difference 18.9%, 95% CI, 0.6%-37.2%), and a Percentage of Glottic Opening score of 100% was achieved in 37/61 (60.7%) in the McGrath VL group versus 23/63 (36.5%) in the DL group (risk difference 22.1%, 95% CI, 6.2%-37.9%). The overall incidence of intubation-related complications did not differ significantly between groups (McGrath VL: 5/61 [8.2%] vs DL: 7/63 [11.1%], risk difference -4.1%, 95% CI, -14.7%-6.4%); however, esophageal intubation occurred in 0/61 (0%) in the McGrath VL group versus 3/63 (4.8%) in the DL group. CONCLUSION: The McGrath VL significantly improves first-attempt intubation success in infants when used by anesthesia trainees, especially among less experienced providers. Video laryngoscopy may enhance safety and effectiveness in infant airway management. These results support its routine use by novice providers in infant anesthesia.

来源:Anesth Analg,查看原文。版权归原作者所有。

引用

  1. Uchinami Y, Fujita N, Hoshino K, et al. Effectiveness of McGRATH MAC Video Laryngoscopy for First-Attempt Intubation by Anesthesia Trainees in Infants: A Randomized Controlled Trial. Anesth Analg. 2026. PMID: 41698200. doi:10.1213/ANE.0000000000007952

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。