文献速递疼痛医学区域麻醉与超声

人工膝关节与天然膝关节膝神经消融解剖靶点是否需要修改的尸体研究

Is there a need to modify the anatomical targets for genicular nerve ablation in prosthetic knees compared with native knees? A cadaveric study.
PubMed 文献 · Reg Anesth Pain Med · 2026-01-22

该尸体研究比较了10例天然膝关节与10例人工膝关节中膝神经的起源、走行、靶点、直径及与血管毗邻关系,发现两组神经靶点差异极小,但人工膝关节组神经直径更小且隐神经髌下支存在纤维化粘连,髌上外侧膝神经靶点附近动脉分支缺失可能降低超声定位准确性。

要点

  • 人工膝关节与天然膝关节的膝神经解剖位置基本相似,但神经直径更小。
  • 人工膝关节组隐神经髌下支因手术纤维化粘连,可能导致术后神经瘤和神经炎。
  • 髌上外侧膝神经靶点附近动脉分支缺失可能降低超声引导准确性。

核心结论

  • 人工膝关节与天然膝关节的膝神经解剖位置可比,但神经直径更小且隐神经髌下支纤维化,解剖差异本身不能完全解释射频消融后疼痛缓解减弱。

研究设计与样本

  • 尸体研究,纳入10例天然膝关节和10例人工膝关节,行乳胶动脉注射并详细解剖膝神经,比较起源、走行、靶点、直径及与动脉毗邻关系。

主要发现

  • 两组膝神经靶点差异极小。
  • 人工膝关节组隐神经髌下支因既往手术出现纤维化粘连,可能导致术后神经瘤和神经炎。
  • 靶点处平均神经直径人工膝关节组小于天然膝关节组。
  • 髌上内侧膝神经靶点至关节线的距离在人工膝关节组更短(4.00±0.43 cm vs 4.53±0.75 cm,p=0.005)。
  • 9例天然膝关节和8例人工膝关节在髌上外侧膝神经靶点附近缺乏动脉分支。

关键数值与推荐

  • 髌上内侧膝神经靶点至关节线距离:人工膝关节组4.00±0.43 cm,天然膝关节组4.53±0.75 cm,p=0.005。
  • 髌上外侧膝神经靶点附近缺乏动脉分支:天然膝关节9例,人工膝关节8例。

临床怎么用

  • 在人工膝关节患者行膝神经射频消融时,应关注隐神经髌下支纤维化粘连及髌上外侧膝神经靶点附近动脉分支缺失对超声定位的影响。

局限性

  • 原文未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Joint replacement is standard of care for chronic knee osteoarthritis, but can cause persistent postsurgical pain. Radiofrequency denervation helps treat chronic knee pain, though its effectiveness is lower in patients with knee arthroplasty than in those with native knees. Our goal was to compare genicular nerve targets in native and prosthetic cadaveric knees and see if targets need modification after arthroplasty. METHODS: 10 native and 10 prosthetic knees from deceased donors underwent latex arterial injection and detailed dissection of the genicular nerves, comparing their origin, course, target points, diameter, and proximity with arterial blood vessels. RESULTS: Minimal differences among genicular nerve targets were observed between the two groups. The prosthetic knees had fibrotic adhesions of the infrapatellar branch of the saphenous nerve (IPBSN) due to previous surgery, potentially causing postsurgical neuromas and neuritis. The average nerve diameter at target points was smaller in prosthetic than native knees. The distance from the target point to the joint line was shorter for the superomedial genicular nerve in the prosthetic knee group (4.00±0.43 cm vs 4.53±0.75 cm, p=0.005). Nine native and eight prosthetic knees lacked an arterial branch near the target point of the superolateral genicular nerve (SLGN). CONCLUSION: Prosthetic knees share comparable genicular nerve anatomic locations with native knees but exhibit smaller nerve diameters and fibrosis of the IPBSN. The absence of a nearby arterial branch to the SLGN may reduce ultrasound targeting accuracy. Anatomical differences alone, however, do not fully explain the diminished pain relief observed after radiofrequency ablation.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Gaspary F, Behets CW, Manon J, et al. Is there a need to modify the anatomical targets for genicular nerve ablation in prosthetic knees compared with native knees? A cadaveric study. Reg Anesth Pain Med. 2026. PMID: 41571427. doi:10.1136/rapm-2025-107379

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。