扩展现实全息辅助胸段硬膜外置入:Thiel尸体随机试验
本研究在Thiel软防腐尸体上比较扩展现实全息辅助与体表标志法胸段硬膜外穿刺的表现,58名麻醉医师完成随机分配部位测试。全息组与标志组的全局评定量表斜率无差异,但全息组平均进针移动次数更少(0.94 vs 1.49,P<0.001),理想操作比例更高但未达统计学显著。
要点
- 全息辅助未改善全局评定量表评分,但减少了进针移动次数。
- 全息组理想操作比例52% vs 28%,RR 1.50(95%CI 0.91-2.53)。
- 研究在Thiel软防腐尸体上进行,非活体患者。
核心结论
- 全息辅助胸段硬膜外穿刺未改变全局评定量表评分,但减少了进针移动次数。
研究设计与样本
- 随机对照试验,58名各级麻醉医师在Thiel软防腐尸体T1/2至T10/11间10个随机分配部位操作。
- 主要结局为全局评定量表评分的log-log斜率。
主要发现
- 全息组与标志组全局评定量表斜率无差异,且不因麻醉医师级别而异。
- 全息组平均进针移动次数对数值为0.94(0.95) vs 1.49(0.97),P<0.001。
- 全息组理想操作(单次皮肤进针且后续移动≤2次)比例52% vs 28%,RR 1.50(95%CI 0.91-2.53)。
临床怎么用
- 全息辅助可能减少胸段硬膜外穿刺中的进针调整次数,但未提升整体操作评分。
- 该技术可作为培训辅助工具探索,临床价值需进一步在活体验证。
局限性
- 研究在Thiel软防腐尸体上进行,非活体患者。
- 理想操作比例的组间差异置信区间包含1,未达统计学显著。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Medical extended reality projects a 3D digital image onto live surface anatomy via a wearable device while allowing operators to interact with the real world. We have developed a 3D hologram of the thoracic spine from CT images of a soft embalmed Thiel cadaver and visualised spinal anatomy through a Microsoft Hololens2 headset. The primary objective of this study was to test whether thoracic epidural training performance on the cadaver was improved using extended reality compared with the landmark insertion technique. METHODS: The study comprised psychometric evaluation of anaesthetists of all grades, a lecture, needling practice on both a plastic simulator, and a soft embalmed Thiel cadaver and familiarisation with the Hololens2. Testing of cadaveric thoracic epidural procedural performance occurred at 10 randomly allocated anatomical sites between T1/2 and T 10/11, randomised equally to the landmark paramedian technique or hologram guidance. Both groups used loss of resistance to fluid as the procedural endpoint. The primary outcome was the log-log slope of Global Rating Scale assessments. RESULTS: For 58 anaesthetists who completed the study, Global Rating Scale slopes did not differ between groups or by grade of anaesthetist. Secondary endpoints showed differences: the mean log number of needle movements was reduced in the extended reality group: 0.94 (0.95) vs 1.49 (0.97), P<0.001; and ideal performance, defined as a single needle insertion through skin and two or fewer subsequent needle movements, was higher in the extended reality group, 52% vs 28%, Relative Risk (RR) 1.50 (0.91-2.53). CONCLUSIONS: Extended reality hologram-assisted thoracic epidural insertion did not alter Global Rating Scale scores for the holographic vs landmark techniques, but reduced needle movements.
引用
- McLeod G, McKendrick M, Portelli R, et al. Thoracic epidural insertion using extended reality hologram assistance: a randomised trial of regional anaesthesia skill performance on the soft embalmed Thiel cadaver. Br J Anaesth. 2026. PMID: 41478802. doi:10.1016/j.bja.2025.10.060
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。