婴儿气管插管中经鼻高流量氧疗:单中心随机对照试验
该单中心随机对照试验纳入132例择期气管插管手术婴儿,比较经鼻高流量氧疗(HFNO)与面罩通气在预氧合及无呼吸氧合中的效果。结果显示两组血氧饱和度低于95%的发生率无显著差异(9.2% vs 13.3%,RR 1.44,95%CI 0.53-3.92,P=0.658),但HFNO组胃充气发生率显著更低(36.7% vs 70.8%,P<0.001)。
要点
- 婴儿气管插管中HFNO与面罩通气的去饱和发生率无显著差异
- HFNO组胃充气发生率显著低于面罩通气组
- HFNO可作为婴儿气管插管预氧合和无呼吸氧合的替代选择
核心结论
- 婴儿气管插管中HFNO与面罩通气的去饱和发生率无显著差异,但HFNO与更低的胃充气发生率相关。
研究设计与样本
- 前瞻性单中心随机对照试验,纳入132例择期气管插管手术婴儿,排除后分析125例(HFNO组60例,对照组65例)。
- 两组均接受100%氧气,HFNO组预氧合0.5 l·kg⁻¹·min⁻¹持续3分钟,无呼吸期2 l·kg⁻¹·min⁻¹持续1分钟,喉镜操作期2 l·kg⁻¹·min⁻¹;对照组面罩预氧合6 l/min持续3分钟,无呼吸期面罩通气6 l/min持续1分钟,喉镜操作期不供氧。
- 主要结局为预氧合至插管后1分钟内外周血氧饱和度低于95%持续5秒或以上的发生率。
主要发现
- 血氧饱和度低于95%的发生率对照组9.2%、HFNO组13.3%,相对风险1.44(95%CI 0.53-3.92,P=0.658),无统计学显著差异。
- 血氧饱和度低于90%发生率、首次插管成功率、最低血氧饱和度、插管后呼气末二氧化碳和氧气、肺不张评分两组相似。
- 胃充气发生率HFNO组36.7%、对照组70.8%,差异有统计学意义(P<0.001)。
临床怎么用
- 婴儿气管插管时可考虑使用HFNO进行预氧合和无呼吸氧合以减少胃充气,但需注意其去饱和发生率与面罩通气无显著差异。
局限性
- 单中心研究,样本量有限,外推性需进一步验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: High-flow nasal oxygenation (HFNO) is increasingly used as an alternative for preoxygenation and apneic oxygenation during tracheal intubation. However, its efficacy in infants remains underexplored. This study evaluated whether HFNO improves intubation outcomes compared to those with face mask ventilation in infants. METHODS: This prospective, single-center randomized controlled trial included 132 infants undergoing elective surgery under tracheal intubation. The infants were divided into HFNO and control groups, with both groups receiving 100% oxygen. The HFNO group received HFNO for preoxygenation (0.5 l · kg -1 · min -1 for 3 min), as well as during the apneic period (2 l · kg -1 · min -1 for 1 min) and laryngoscopy (2 l · kg -1 · min -1 ). The control group received face mask preoxygenation (6 l/min for 3 min), followed by face mask ventilation during the apneic period (6 l/min for 1 min) and no oxygen delivery during laryngoscopy. The primary outcome was the desaturation incidence (peripheral oxygen saturation of less than 95% for 5 s or longer) from preoxygenation to 1 min after intubation. Various secondary outcomes were also assessed. RESULTS: After exclusions, 125 infants were analyzed (HFNO: n = 60; control: n = 65). There was no statistically significant between-group difference in the incidence of oxygen saturation less than 95% (control vs . HFNO: 9.2% vs . 13.3%; relative risk, 1.44; 95% CI, 0.53 to 3.92; P = 0.658). With regard to secondary outcomes, the incidence of oxygen saturation less than 90%, first-attempt intubation success rate, lowest oxygen saturation, postintubation end-tidal carbon dioxide and oxygen, and atelectasis scores were similar between groups. Gastric insufflation was less frequent in the HFNO group; the difference was statistically significant (36.7% vs . 70.8%; P < 0.001). CONCLUSIONS: In the current study involving the use of HFNO for preoxygenation and apneic oxygenation during tracheal intubation in infants, there was no significant difference in the incidence of desaturation between HFNO and face mask ventilation, although the former was associated with less frequent gastric insufflation.