术前呼出气一氧化氮与呼吸力学预测儿童全麻呼吸道结局的可行性
该可行性研究纳入120名儿童(最终分析116名),按有无呼吸道症状分组,术前测量呼出气一氧化氮(FeNO)和强迫振荡技术(FOT)呼吸力学,记录围术期呼吸不良事件。FeNO和FOT分别成功测量106/116(91%)和71/116(61%),围术期呼吸不良事件发生17/116(15%),两组无差异(OR 2.11,95%CI 0.74-6.55),两项检测均未预测事件发生。
要点
- 术前FeNO测量可行(91%成功),但FOT呼吸力学测量困难(61%成功)。
- 围术期呼吸不良事件发生率15%,症状组与对照组无显著差异。
- FeNO和FOT均未能可靠预测儿童围术期呼吸不良事件。
核心结论
- 术前FeNO测量可行,但FOT呼吸力学测量困难,两者均未改善围术期呼吸不良事件的预测。
- 详尽的术前临床病史结合有经验的儿科麻醉医生照护仍是减少围术期呼吸不良事件最可靠的手段。
研究设计与样本
- 可行性研究,将120名儿童按有无呼吸道症状分为呼吸组和对照组,最终116名纳入分析。
- 术前记录FeNO和强迫振荡技术(FOT)呼吸力学,随访围术期呼吸不良事件发生率。
主要发现
- FeNO和FOT呼吸力学分别成功记录于106/116(91%)和71/116(61%)的儿童。
- 围术期呼吸不良事件发生于17/116(15%)患者,两组间无差异(OR 2.11,95%CI 0.74-6.55)。
- 术前FeNO水平未预测围术期呼吸不良事件的发生。
- FOT呼吸力学测量未预测围术期呼吸不良事件。
临床怎么用
- 术前FeNO测量在儿童中可行,但FOT呼吸力学测量实施困难,均不宜用于常规预测围术期呼吸不良事件。
- 应重视详尽术前临床病史和有经验的儿科麻醉医生照护以降低围术期呼吸不良事件。
局限性
- 本研究为可行性研究,样本量有限(最终分析116名),预测效能结论需谨慎解读。
- FOT呼吸力学测量成功率仅61%,可能影响其预测价值的评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Peri-operative respiratory adverse events remain a major cause of morbidity and mortality in children undergoing general anaesthesia; those with asthma are at higher risk. The aim of this feasibility study was to determine whether pre-operative measurements of fractional exhaled nitric oxide and the forced oscillation technique are feasible in children, and to explore whether these measurements can predict peri-operative respiratory adverse events. METHODS: We assigned children into respiratory or control groups, according to the presence or absence of respiratory symptoms. We recorded pre-operative measurements of fractional exhaled nitric oxide as well as respiratory mechanics, as determined by the forced oscillation technique. We then recorded the incidence of peri-operative respiratory adverse events. RESULTS: We enrolled 120 children of which 116 were included. Fractional exhaled nitric oxide and respiratory mechanics (forced oscillation technique) were recorded in 106/116 (91%) and 71/116 (61%), respectively. Peri-operative respiratory adverse events occurred in 17/116 (15%) patients but there was no difference between groups (OR 2.11, 95%CI 0.74-6.55). Pre-operative fractional exhaled nitric oxide levels did not predict the occurrence of peri-operative respiratory adverse events. The measurement of respiratory mechanics using the forced oscillation technique did not predict peri-operative respiratory adverse events. DISCUSSION: We have shown the feasibility of study enrolment and pre-operative fractional exhaled nitric oxide measurement but had difficulty obtaining measurements of respiratory mechanics (forced oscillation technique). Neither test improved the prediction of peri-operative respiratory adverse events reliably in this group of patients. A thorough pre-operative clinical history combined with care by an experienced paediatric anaesthetist remains the most reliable means of reducing peri-operative respiratory adverse events. Breathing problems during and after an operation can sometimes make children very sick. These problems happen more often in children with asthma. In this study, we wanted to see if two special breathing tests could help doctors find out which children might have breathing problems during an operation. The two tests were called the fractional exhaled nitric oxide test and the forced oscillation technique. We put the children into two groups: one group had breathing symptoms (like coughing or wheezing) and the other group did not. Before their operations, we measured their breathing using the two tests. Then, we kept track of any breathing problems they had during or after their operation. We started with 120 children, and 116 were part of the final study. We were able to do the first test (the nitric oxide test) in 91% of the children and the second test (the oscillation test) in 61% of them. About 15% of the children (17 out of 116) had breathing problems around the time of their operation. However, there was no big difference between the two groups. The breathing tests did not help us predict which children would have breathing problems. We found that it was possible to do the study and use the nitric oxide test before the operation, but the oscillation test was harder to do. Neither test helped doctors tell which children might have breathing problems. The best way to keep children safe is still for doctors to take a careful medical history and for experienced children's anaesthetists to look after them during the operation.
引用
- Hauser N, Sommerfield D, Nguyen J, et al. Feasibility of the pre-operative measurement of fractional exhaled nitric oxide and respiratory mechanics to predict respiratory outcomes in children undergoing general anaesthesia. Anaesthesia. 2025. PMID: 41208566. doi:10.1111/anae.70056
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。