可乐定不影响婴儿脊髓麻醉下的睡眠纺锤波与年龄相关脑电模式
本研究对73例脊髓麻醉婴儿术中额叶脑电进行分析,比较布比卡因与布比卡因+可乐定的脑电频谱及睡眠纺锤波特征。结果显示两组频谱功率和纺锤波检测概率无差异(P=.51);年龄增长与0-0.6 Hz功率降低、2-15 Hz功率升高及纺锤波强度增加相关,脑电变化与生理睡眠相似。
要点
- 婴儿脊髓麻醉中可乐定不改变脑电睡眠纺锤波特性。
- 脊髓麻醉下婴儿脑电显示与生理睡眠相似的年龄相关变化。
- 可乐定可延长脊髓麻醉 duration 而不影响生理睡眠脑电模式。
核心结论
- 低剂量可乐定不影响婴儿脊髓麻醉下脑电的睡眠纺锤波特性。
- 脊髓麻醉下婴儿脑电呈现与安静生理睡眠相似的年龄相关变化。
- 鞘内可乐定不改变年龄相关脑电模式,可延长麻醉 duration 而不影响生理睡眠脑电。
研究设计与样本
- 对73例脊髓麻醉婴儿获取术中额叶脑电记录。
- 使用非参数多锥度频谱分析比较布比卡因与布比卡因+可乐定的脑电频谱特征。
- 应用切换状态空间模型提取并比较睡眠纺锤波特征,并比较年轻与年长婴儿。
主要发现
- 布比卡因与布比卡因+可乐定组间功率谱和睡眠纺锤波检测概率无差异(P=.51)。
- 年龄增长与0至0.6 Hz频谱功率降低相关(中位差值-2.9 dB,95%CI[-5.3,-0.5])。
- 年龄增长与2至15 Hz功率升高相关(中位差值3.4 dB,95%CI[1.5,5.2])。
- 年龄增长与纺锤波强度增加相关(R²=0.323,F(2,67)=15.98,P<0.001)。
- 上述脑电表现与婴儿生理睡眠中的发现相似。
临床怎么用
- 婴儿脊髓麻醉中使用可乐定延长阻滞 duration 时,无需担心其改变生理睡眠脑电模式。
- 婴儿脊髓麻醉下脑电年龄相关变化可作为生理睡眠的参考,无需因可乐定而调整脑电判读。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Spinal anesthesia is an alternative to general anesthesia in infants. A caveat of spinal anesthesia in infants is short block duration. Clonidine is a common adjunct that prolongs spinal anesthesia. The mechanisms by which clonidine prolongs spinal anesthesia are unknown. Infants under spinal anesthesia appear in a sleep-like state. We hypothesized that infants receiving bupivacaine spinal anesthesia with clonidine may exhibit more sleep spindles on the electroencephalogram (EEG). METHODS: We obtained intraoperative frontal EEG recordings in 73 infants under spinal anesthesia. We compared EEG spectral features of bupivacaine and bupivacaine + clonidine spinal anesthesia using nonparametric multitaper spectral analysis. A recently developed switching state-space modeling approach was then applied to extract and compare spindle features in bupivacaine versus bupivacaine + clonidine spinal anesthesia. We then applied the same model to compare younger versus older infants. RESULTS: There was no difference in the power spectra and sleep spindle detection probability between bupivacaine and bupivacaine + clonidine spinal anesthesia ( P = .51). We found age-related EEG changes in both bupivacaine and bupivacaine + clonidine spinal anesthesia independent of clonidine. Increasing age was associated with decreased spectral power from 0 to 0.6 Hz (median difference -2.9 dB, 95% CI [-5.3, -0.5,]) and increased power from 2 to 15 Hz (median difference 3.4 dB, 95% CI [1.5, 5.2]). Increasing age was also associated with increased spindle strength (R 2 = 0.323, F(2,67) = 15.98, P < 0.001). These EEG findings mirror those found in infants under physiologic sleep. CONCLUSIONS: Our findings suggest that low-dose clonidine does not impact sleep spindle properties in the EEG of infants under spinal anesthesia. The EEG of infants under spinal anesthesia demonstrate age-related changes that mirror quiet physiologic sleep. In addition, the presence of intrathecal clonidine has no effect on the age-related changes in the EEG pattern. Clonidine is an adjunct for spinal anesthesia in infants that appears to prolong anesthetic duration without affecting their EEG patterns of physiologic sleep.
引用
- Chen AL, He M, Agrawal U, et al. Clonidine Conserves Sleep Spindle Properties and Age-Dependent Electroencephalogram Patterns Mirroring Physiologic Sleep in Infants Under Spinal Anesthesia. Anesth Analg. 2025. PMID: 40956769. doi:10.1213/ANE.0000000000007763
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。