文献速递区域麻醉与超声气道管理

增强现实引导的颅面与气道神经阻滞培训用于麻醉住院医师

Augmented reality-guided craniofacial and airway nerve block training for anesthesiology residents.
PubMed 文献 · Reg Anesth Pain Med · 2026-10-05

这项探索性研究评估了增强现实(AR)引导能否提升麻醉科教师和住院医师的神经阻滞表现。20名参与者在有无AR引导下分别完成眶下、下牙槽、喉上和舌咽神经阻滞,结果显示AR与无AR的临床可接受率相似(65.0% vs 55.0%,McNemar p=0.754),但AR显著延长了操作时间(总体49.9±8.4 vs 14.5±2.6 s,Wilcoxon p<0.001)。

要点

  • AR引导未显著提高神经阻滞的临床可接受率
  • AR引导显著延长了操作时间
  • AR引导用于颅面与气道神经阻滞培训具有可行性

核心结论

  • 在这项小型探索性研究中,AR未显著影响教师或住院麻醉医师完成临床可接受神经阻滞的比率,但显著增加了操作所需时间。
  • 该概念验证研究成功证明了使用商用技术学习或实施多种颅面与气道神经阻滞的可行性。

研究设计与样本

  • 探索性研究,20名麻醉科教师和住院医师参与。
  • 参与者在有无AR引导下分别完成眶下、下牙槽、喉上和舌咽神经阻滞;AR引导使用Hololens头显和SurgicalAR软件,将DICOM重建叠加于供体头部,并通过定位器械实时追踪物理针沿预映射虚拟针路径。
  • 通过基于解剖的准确性(亚甲蓝与神经的邻近程度)和操作时间评估表现。

主要发现

  • AR与无AR条件下的总体临床可接受率相似(65.0% vs 55.0%,McNemar p=0.754)。
  • 按培训水平分层,表现无差异(住院医师McNemar p=0.219;教师McNemar p=0.625)。
  • AR显著增加操作时间(总体49.9±8.4 vs 14.5±2.6 s,Wilcoxon p<0.001),且时间增加在各培训水平一致(教师:+34.9 s,p=0.016;住院医师:+36.0 s,p=0.062)。
  • DICOM叠加于供体的覆盖模式与DICOM悬浮于供体上方或旁边的分离模式之间,神经阻滞成功率或操作时长无差异。

临床怎么用

  • AR引导可用于颅面与气道神经阻滞的学习或操作,但需注意其可能延长操作时间。

局限性

  • 样本量小(20名参与者),为探索性研究。
  • 仅评估了可行性,未证明AR优于传统方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The acquisition of craniofacial and airway nerve block (ANB) skills is hindered by the complex anatomy involved, reliance on landmark-guided techniques, and the absence of simulation-based training tools. Augmented reality offers a promising platform for procedural training by providing real-time visual feedback, yet its potential to improve accuracy in ANBs has not been evaluated. This exploratory study assessed the feasibility of AR guidance for improving nerve block performance among anesthesiology faculty and residents.20 participants performed infraorbital, inferior alveolar, superior laryngeal, and glossopharyngeal nerve blocks with and without AR guidance using volumetric Digital Imaging and Communications in Medicine (DICOM) reconstructions superimposed on body donor heads via Hololens headset, from Microsoft Corporation and SurgicalAR software from Medivis. AR guidance included a localizer instrument for real-time tracking of a physical needle along a premapped virtual needle path. Performance was assessed by dissection-based accuracy (proximity of methylene blue to the nerve) and procedure time.Overall clinical acceptability was similar between AR and non-AR conditions (65.0% vs 55.0%, McNemar's p=0.754). There were no differences in performance when stratified by level of training (McNemar p=0.219 for residents; McNemar p=0.625 for faculty). However, AR significantly increased procedure time (overall 49.9±8.4 vs 14.5±2.6 s, Wilcoxon p<0.001) and time increases were consistent across training levels (faculty: +34.9 s, p=0.016; residents: +36.0 s, p=0.062). Additionally, there was no difference in nerve block success or procedure length between an overlay mode with the DICOM superimposed onto the body donor and a detached mode with the DICOM floating above or next to the body donor.In this small, exploratory study, AR did not significantly impact the rates of clinically acceptable nerve blocks when performed by faculty or resident anesthesiologists; however, AR significantly increased the amount of time required to perform the procedures. This proof-of-concept study successfully demonstrated the feasibility of using AR to learn and/or perform various craniofacial and ANBs using commercially available technology.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Zheng D, Mercer CN, Lau N, et al. Augmented reality-guided craniofacial and airway nerve block training for anesthesiology residents. Reg Anesth Pain Med. 2026. PMID: 40992897. doi:10.1136/rapm-2025-106776

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。