文献速递气道管理心胸血管麻醉

高角度视频喉镜片增加气管插管时短暂窦性停搏发生率

Incidence of transient sinus pause in cardiac rhythm increases with the use of hyperangulated videolaryngoscope blade compared to standard angle blade during tracheal intubation: A prospective randomised controlled trial.
PubMed 文献 · Eur J Anaesthesiol · 2026-02-13

这项前瞻性随机对照试验纳入134例全麻患者,比较标准角度与高角度视频喉镜片气管插管时血流动力学变化。高角度组短暂窦性停搏发生率显著高于标准组(19% vs 4%,P=0.009),多因素分析显示高角度镜片是独立预测因子(OR=5.73,95%CI 1.53–21.53;P=0.010)。

要点

  • 高角度视频喉镜片插管时短暂窦性停搏发生率为19%,标准角度为4%。
  • 高角度镜片是插管期间短暂窦性停搏的独立预测因子(OR=5.73)。
  • 高角度组声门开放评分更高、BURP按压更少,但镜片在口腔内时间更长。

核心结论

  • 高角度视频喉镜片气管插管时短暂窦性停搏发生率高于标准角度镜片(19% vs 4%,P=0.009)。
  • 多因素logistic分析显示使用高角度镜片是插管期间短暂窦性停搏的独立预测因子(OR=5.73,95%CI 1.53–21.53;P=0.010)。

研究设计与样本

  • 前瞻性随机对照试验,单中心三级大学医院开展。
  • 最终分析纳入134例择期全麻气管插管患者。

主要发现

  • 高角度组短暂窦性停搏发生率显著高于标准组(19% vs 4%,P=0.009)。
  • 高角度组声门开放评分百分比显著更高,BURP按压发生率显著更低。
  • 高角度组直接会厌抬起发生率显著更高,镜片在口腔内总时间显著更长。

关键数值与推荐

  • 主要观察指标为气管插管期间短暂心率下降或短暂窦性停搏的发生。
  • 高角度镜片预测短暂窦性停搏的OR=5.73,95%CI 1.53–21.53,P=0.010。

临床怎么用

  • 使用高角度视频喉镜片插管时应警惕短暂窦性停搏,加强心律监测。
  • 对心动过缓高风险患者,选择镜片角度时需权衡声门暴露优势与心律风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The hyperanglulated videolaryngoscope blade may exert different forces on the larynx compared to the standard angle blade, potentially leading to haemodynamic changes, particularly in cardiac rhythm. OBJECTIVE: This study aimed to investigate the impact of the hyperangulated blade on haemodynamic changes during tracheal intubation. DESIGN: A prospective randomised controlled trial. SETTING: Tertiary, university hospital, single centre. PATIENTS: A total of 134 patients scheduled for general anaesthesia were included in the final analysis. INTERVENTION: Tracheal intubation using either a standard angle videolaryngoscope blade (Standard group) or a hyperangulated blade (Hyperangulated group). MAIN OUTCOME MEASURES: The occurrence of a transient decrease in heart rate or a transient sinus pause during tracheal intubation was recorded. RESULTS: The incidence of transient sinus pause was significantly higher in the Hyperangulated group compared to the Standard group (19% vs. 4%, respectively, P = 0.009). The percentage of the glottic opening score was significantly higher, and the incidence of backward, upward, and rightward pressure was significantly lower in the Hyperangulated group. The incidences of direct epiglottis lifting was significantly higher in the Hyperangulated group, and the total length of time of the blade in the mouth was significantly longer in the Hyperangulated group. Multivariate logistic analysis identified the use of a hyperangulated blade as an independent predictor of transient sinus pause during tracheal intubation (odds ratio = 5.73, 95% confidence interval = 1.53 to 21.53; P = 0.010). CONCLUSION: The hyperangulated videolaryngoscope blade is associated with a higher incidence of transient sinus pause than the standard angle blade during tracheal intubation. TRIAL REGISTRATION: Clinical Research Information Service. Korea Centers for Disease Control and Prevention, Ministry of Health and Welfare (Republic of Korea). (Identifier: KCT0006534). http://cris.nih.go.kr .

来源:Eur J Anaesthesiol,查看原文。版权归原作者所有。

引用

  1. Lee YJ, Lee S, Kim JW, et al. Incidence of transient sinus pause in cardiac rhythm increases with the use of hyperangulated videolaryngoscope blade compared to standard angle blade during tracheal intubation: A prospective randomised controlled trial. Eur J Anaesthesiol. 2026. PMID: 40702899. doi:10.1097/EJA.0000000000002243

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。