基于体重指数调整呼气末正压对全麻患者驱动压及肺通气的影响:一项随机对照试验
该单中心随机对照优效性试验纳入60例全麻气管插管非心胸手术成人患者,比较标准PEEP(5 cmH2O)与按BMI/3设定PEEP对驱动压和围术期肺通气丧失的影响。结果显示BMI/3组驱动压显著降低、呼吸系统顺应性更高,术后肺通气丧失减少,且补充氧需求更少、新发肺不张更少、入PACU时氧饱和度更高。
要点
- 按BMI/3设定PEEP较标准PEEP 5 cmH2O显著降低驱动压并提高呼吸系统顺应性。
- BMI/3组术后肺超声示肺通气丧失减少,新发肺不张更少,入PACU氧饱和度更高。
- 对无严重肺疾病的全麻气管插管非心胸手术患者,BMI/3是个体化PEEP的简便方法。
核心结论
- 在无严重肺疾病的全麻气管插管非心胸手术患者中,按BMI/3调整PEEP可改善肺力学并减少术后肺通气丧失。
研究设计与样本
- 随机对照、患者盲法、单中心优效性试验,两组平行,纳入60例全麻气管插管成人手术患者。
- 随机分为标准PEEP组(PEEP=5 cmH2O)与BMI调整PEEP组(PEEP=BMI/3 cmH2O)。
- 容量控制通气,潮气量7 ml.kg-1预测体重;术前术后用超声评估肺通气评分。
主要发现
- 驱动压中位数(IQR[范围])PEEP-5组为8.9(7.1-10.4[5.2-14.9])cmH2O,PEEP-BMI/3组为7.9(7.2-8.5[5.9-14.1])cmH2O,p=0.027。
- 呼吸系统顺应性均值(SD)PEEP-5组为0.83(0.20)ml cmH2O-1 kg-1预测体重,PEEP-BMI/3组为0.95(0.17)ml cmH2O-1 kg-1预测体重,p=0.020。
- 肺超声显示BMI/3组术后肺通气丧失减少。
- BMI调整组补充氧需求更少、新发肺不张更少、入PACU时氧饱和度更高。
临床怎么用
- 对无严重肺疾病的全麻气管插管非心胸手术成人患者,可按BMI/3计算PEEP(约7-10 cmH2O)进行个体化设置。
- 该方法简便实用,有助于改善术中肺力学并减少术后肺通气丧失。
局限性
- 单中心研究,样本量60例,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Lung-protective ventilation is essential for preventing postoperative pulmonary complications. While maintaining a low driving pressure and optimising PEEP is of importance, the ideal strategy remains contentious. This study evaluated whether adjusting PEEP based on BMI, compared with standard PEEP, could reduce driving pressure and peri-operative loss of lung aeration. METHODS: We conducted a randomised controlled, patient-blinded, single-centre superiority trial with two parallel groups. Adult patients undergoing surgery with general anaesthesia who required tracheal intubation were assigned randomly to either standardised PEEP (PEEP = 5 cmH2O; group PEEP-5) or PEEP set according to BMI (PEEP = BMI/3 cmH2O; group PEEP-BMI/3). Patients' lungs were ventilated using a volume-controlled mode with tidal volumes of 7 ml.kg-1 predicted body weight. Lung aeration scores were assessed using ultrasound pre- and postoperatively. RESULTS: Sixty patients were enrolled and allocated randomly. Adjustment of PEEP according to BMI/3 was associated with a significantly lower driving pressure, with a median (IQR [range]) of 8.9 (7.1-10.4 [5.2-14.9]) cmH2O in group PEEP-5 and 7.9 (7.2-8.5 [5.9-14.1]) cmH2O in group PEEP-BMI/3 (p = 0.027) and higher mean (SD) respiratory system compliance (group PEEP-5, 0.83 (0.20) ml cmH2O-1 kg-1 predicted body weight vs. group PEEP-BMI/3, 0.95 (0.17) ml cmH2O-1 kg-1 predicted body weight; p = 0.020). Lung ultrasound revealed a reduced postoperative loss of lung aeration in patients allocated to the BMI/3 group. Patients allocated to the BMI-adjusted group required less supplemental oxygen, had less newly developed atelectasis and had higher oxygen saturations upon arrival in the post-anaesthesia care unit. DISCUSSION: In patients without major pulmonary disease who were undergoing non-cardiothoracic surgeries with tracheal intubation, adjusting PEEP based on a calculation of BMI/3 improved lung mechanics and reduced postoperative loss of lung aeration. This approach provides a straightforward and pragmatic method for individualising PEEP in patients undergoing general anaesthesia. Protecting the lungs during surgery is important to stop problems with breathing afterwards. One way to do this is by using the right air pressure when helping someone breathe with a machine. But doctors don't all agree on the best way to do this. This study looked at whether using air pressure based on a person's body size (BMI) is better than using the same air pressure for everyone. We did a study with two groups of adult patients who were having surgery and needed help breathing with a tube and machine. Some patients got the same air pressure (5 cmH2O), while others got air pressure based on their BMI (BMI divided by 3, about 7‐10 cmH2O). We used a special setting on the breathing machine that gave each person the same amount of air based on their body size. We used ultrasound to check how well their lungs were working before and after surgery. We studied 60 people. The group that got air pressure based on BMI had better results. Their lungs needed less pressure to work properly, and they had better lung movement. Their lungs also stayed more open after surgery. They needed less extra oxygen, had fewer new breathing problems, and had better oxygen levels after surgery. In people without serious lung problems, using air pressure based on BMI during surgery helped their lungs work better and kept them healthier afterward. This method is simple and can be a good way for doctors to choose the best air pressure for each patient during surgery.
引用
- Selpien H, Penon J, Thunecke D, et al. Adjustment of positive end-expiratory pressure based on body mass index during general anaesthesia: a randomised controlled trial. Anaesthesia. 2025. PMID: 40551551. doi:10.1111/anae.16656
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。