基于动态动脉弹性指导腹部大手术术中液体管理的随机临床试验
在胰十二指肠切除术患者中,比较基于动态动脉弹性(Ea dyn)与每搏变异度(SVV)治疗术中低血压对组织灌注的影响。主要终点拔管后1小时乳酸两组相似,但Ea dyn组液体平衡更低、氧耗更高,乳酸从关筋膜到拔管后1小时下降更显著。
要点
- Ea dyn方案未降低拔管后1小时乳酸,但显著减少液体平衡。
- Ea dyn组使用更多血管升压药,氧耗更高。
- 术后并发症与住院时间两组无显著差异。
核心结论
- 包含Ea dyn的低血压处理方案未降低腹部大手术后的乳酸水平,但与液体平衡显著减少和氧耗增加相关。
研究设计与样本
- 随机开放标签临床试验,在高容量胰腺手术三级中心进行;58例拟行胰十二指肠切除术患者中46例符合研究条件。
主要发现
- 拔管后1小时(T3)乳酸水平对照组与Ea dyn组相似。
- Ea dyn组T3氧耗更高,乳酸从关筋膜(T2)到T3显著下降:中位数[IQR] -24.5 [-30至-14]% 对 0 [-24至7.6]%,P=0.004。
- Ea dyn组接受更多血管升压药,T3液体平衡更低:2700 [2100至3800] ml 对 2200 [1060至3000] ml,P=0.020。
- 术后并发症或住院时间无显著差异。
关键数值与推荐
- 对照组低血压(平均动脉压<65 mmHg)依据每搏变异度(SVV)处理,实验组依据动态动脉弹性(Ea dyn)评估处理。
- 主要终点为拔管后1小时乳酸值;次要终点包括液体平衡、术中低血压和术后并发症。
临床怎么用
- 在腹部大手术中,Ea dyn指导的低血压管理可减少液体正平衡,但需预期更多血管升压药使用,且不改善拔管后乳酸。
局限性
- 原文未报告局限性内容。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Arterial hypotension during major surgery is related to postoperative complications and mortality. Both fluids and vasopressors increase blood pressure (BP) by inducing different physiological response. We devised a protocol which relies on dynamic arterial elastance (Ea dyn ) to guide BP optimisation during major abdominal surgery, and tested its effectiveness on tissue perfusion. OBJECTIVE: To explore if an Ea dyn -based optimisation protocol could affect lactate levels, fluid administration, and postoperative clinical complications. DESIGN: Randomised open-label clinical trial. SETTING: High-volume tertiary care centre for pancreatic surgery. PATIENTS: From 58 patients scheduled for cephalic duodenopancreatectomy 46 were eligible for the study. MAIN OUTCOMES AND MEASURES: The primary endpoint was the lactate value one hour after extubation. Secondary endpoints were fluid balance, intra-operative hypotension and postoperative complications. In the control group, hypotension (mean arterial pressure < 65 mmHg) was treated based on stroke volume variation (SVV) while in the experimental group the treatment was based on assessment of dynamic arterial elastance (Ea dyn group). Patient demographic and pre-operative laboratory data were recorded. All haemodynamic data, including oxygen delivery and consumption, were recorded at four time points: after intubation (T0), after fascia opening (T1), after fascia closing (T2) and one hour after extubation (T3). RESULTS: The patients were 70 [63 to 76] years and 15 (33%) were ASA 3. Lactate levels at T3 were similar between the control and Ea dyn groups. Oxygen consumption was higher in the Ea dyn group at T3, and lactate had a significant percentage decrease from T2 to T3: median [IQR], -24.5 [-30 to -14] vs. 0 [-24 to 7.6]%, P = 0.004). Those in Ea dyn group received more vasopressors and had a lower fluid balance at T3: 2700 [2100 to 3800] vs. 2200 [1060 to 3000] ml, P = 0.020). There were no significant differences either in postoperative complications or hospital stay. CONCLUSIONS: A protocol including Ea dyn to treat hypotension did not reduce lactate after major abdominal surgery, but it was associated with a significant reduction in fluid balance and increase in oxygen consumption. TRIAL REGISTRATION: ClinicalTrials.gov NCT05187273.
引用
- Russo A, Aceto P, Cascarano L, et al. A dynamic elastance-based protocol to guide intra-operative fluid management in major abdominal surgery: A randomised clinical trial. Eur J Anaesthesiol. 2025. PMID: 40070308. doi:10.1097/EJA.0000000000002162
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。