文献速递区域麻醉与超声术前评估与围术期医学

左心室辅助装置患者择期全膝关节置换术的原发椎管内麻醉

Primary neuraxial anesthetic for elective total knee arthroplasty in patient with left ventricular assist device.
PubMed 文献 · Reg Anesth Pain Med · 2026-01-05

本文报告一例携带HeartMate 3左心室辅助装置(LVAD)的患者在三级学术中心成功接受椎管内麻醉下择期全膝关节置换术。术前经胸超声心动图显示心脏功能稳定,射血分数为10-15%。原发麻醉为 lumbar epidural,缓慢滴定至手术麻醉平面,术前放置收肌管周围神经导管用于术后镇痛。术中灌注师监测LVAD功能,患者血流动力学稳定,术后病程平稳。结论认为,经适当术前规划和围术期管理,LVAD患者可考虑椎管内麻醉。

要点

  • LVAD患者非心脏手术麻醉选择有限,椎管内麻醉数据稀缺。
  • 本例LVAD患者经椎管内麻醉成功完成择期全膝关节置换术。
  • 术前规划与围术期管理是LVAD患者椎管内麻醉成功的关键。

核心结论

  • 经适当术前规划和围术期管理,LVAD患者可考虑椎管内麻醉。

研究设计与样本

  • 病例报告,一例LVAD患者在全膝关节置换术中接受椎管内麻醉。

主要发现

  • 术前经胸超声心动图显示心脏功能稳定,射血分数为10-15%,携带HeartMate 3 LVAD。
  • 原发麻醉为 lumbar epidural,缓慢滴定至手术麻醉平面,术前放置收肌管周围神经导管用于术后镇痛。
  • 术中灌注师监测LVAD功能,患者血流动力学稳定,术后病程平稳。

临床怎么用

  • LVAD患者行择期非心脏手术时,可经术前规划和围术期管理考虑椎管内麻醉。
  • 椎管内麻醉可缓慢滴定至手术麻醉平面,并联合周围神经导管用于术后镇痛。
  • 术中应由灌注师监测LVAD功能。

局限性

  • 本文为单例病例报告,证据有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is a rising number of patients with left ventricular assist devices (LVADs) undergoing non-cardiac procedures, both emergent and elective. Historically, anesthetic options for these patients have been limited to general anesthesia. Limited data exists for the use of neuraxial anesthesia in patients with LVADs despite its common use in orthopedic procedures for non-LVAD patients. Given the benefits of neuraxial anesthesia and the rising population of LVAD patients undergoing elective procedures, a better understanding of LVAD patients' candidacy for neuraxial anesthesia needs further investigation. CASE PRESENTATION: We report the case of a patient with an LVAD who successfully underwent a total knee arthroplasty with neuraxial anesthesia at a tertiary academic center. Preoperative transthoracic echo demonstrated stable cardiac function and an ejection fraction of 10-15% with a HeartMate 3 LVAD. The primary anesthetic was a lumbar epidural that was slowly titrated to a surgical anesthetic level and an adductor canal peripheral nerve catheter was placed preoperatively for postoperative analgesia. The patient remained hemodynamically stable throughout the case, with a perfusionist monitoring the LVAD's function intraoperatively, and tolerated the anesthetic well. His postoperative course was uneventful. CONCLUSION: Patients with LVADs should be considered candidates for neuraxial anesthesia with appropriate preoperative planning and perioperative management.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。

引用

  1. Sheikh H, Klein JI, Higgins KE, et al. Primary neuraxial anesthetic for elective total knee arthroplasty in patient with left ventricular assist device. Reg Anesth Pain Med. 2026. PMID: 39933835. doi:10.1136/rapm-2024-106253