FRONT阻滞:针对股支与闭孔神经干的股骨头侧双平面注射尸体研究
本研究在8具防腐尸体共15侧进行FRONT阻滞(股支与闭孔神经干双点注射),于髂腰肌平面和耻骨下间隙各沉积染料,随后解剖评估染料扩散。结果显示86.7%的尸体侧成功覆盖股神经感觉髋关节支和闭孔神经干,进针点位于髂前上棘远端6.7 cm(SD 1.6)、内侧偏移1.8 cm(SD 2.1),针道距股神经0.8 cm(SD 0.4)、距股外侧皮神经3.7 cm(SD 2.1)。结论认为FRONT阻滞可可靠覆盖髋关节前部及关节囊,临床应用需熟练掌握超声引导区域麻醉。
要点
- FRONT阻滞通过髂腰肌平面和耻骨下间隙双点注射,同时覆盖股神经感觉髋关节支和闭孔神经干。
- 86.7%的尸体侧实现目标神经覆盖,进针点参考髂前上棘远端6.7 cm、内侧1.8 cm。
- 针道距股神经仅0.8 cm,操作需超声引导以避免神经损伤。
核心结论
- FRONT阻滞能可靠覆盖髋关节前部及关节囊,但操作者需具备超声引导区域麻醉的熟练技能。
研究设计与样本
- 尸体解剖研究,纳入8具防腐尸体共15侧,在超声引导下实施FRONT阻滞后解剖评估染料扩散。
主要发现
- 86.7%的尸体侧成功覆盖股神经感觉髋关节支和闭孔神经干。
- 进针点位于髂前上棘远端6.7 cm(SD 1.6)、内侧偏移1.8 cm(SD 2.1)。
- 针道距股神经平均0.8 cm(SD 0.4),距股外侧皮神经平均3.7 cm(SD 2.1)。
关键数值与推荐
- 主要结局为染料扩散至股神经感觉髋关节支和闭孔神经干,成功率为86.7%。
- 次要结局包括确定准确注射的解剖标志及测量针道至股神经和股外侧皮神经的距离。
临床怎么用
- 临床实施FRONT阻滞时,可参考髂前上棘远端6.7 cm、内侧1.8 cm的进针点,并借助超声动态引导。
- 因针道距股神经仅0.8 cm,需注意避免神经损伤。
局限性
- 研究为尸体解剖,样本量有限(8具尸体15侧),结果需临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The quest for a single nerve block to anesthetize all anterior hip articular nerve branches has long been a challenge for anesthetists, particularly in targeting the obturator nerve (ON). The FRONT block (Femoral Rami Obturator Nerve Trunk) is a newly developed dual-injection technique providing comprehensive anesthetic coverage of the anterior hip joint by targeting both the sensory femoral rami and the ON trunk. METHODS: 15 intact cadaveric sides from eight embalmed cadavers were dissected after FRONT block administration with one injection and two dye deposits in the iliopsoas plane and in the subpectineal compartment under dynamic ultrasonography. The primary outcome was dye spread to the sensory hip articular branches of the femoral nerve (FN) and the ON trunk evaluated during the gross anatomical dissection. Secondary outcomes included identifying landmarks for accurate injection of dye and measuring the distance from the needle trajectory to the femoral and the lateral femoral cutaneous nerves (LFCN). RESULTS: In 86.7% of cadaver sides, the FRONT block successfully covered both the sensory femoral rami and the ON trunk. The injection was performed 6.7 cm (SD 1.6) distal to the anterior superior iliac spine with a medial deviation of 1.8 cm (SD 2.1). The average distance from the needle trajectory to the FN was 0.8 cm (SD 0.4) and 3.7 (SD 2.1) cm to the LFCN. CONCLUSION: The FRONT block offers reliable coverage of the anterior hip joint and capsule. Proficiency in ultrasound-guided regional anesthesia is important during clinical applications.
引用
- Jessen C, Bjørn S, Hörmann R, et al. FRONT block: a cadaveric study of a dual-plane injection block targeting femoral rami and obturator nerve trunk for anterior hip joint analgesia. Reg Anesth Pain Med. 2026. PMID: 39965888. doi:10.1136/rapm-2024-106272
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。