文献速递产科麻醉区域麻醉与超声

硬膜外针与导管注射负荷剂量对分娩镇痛起效时间的比较:前瞻性双盲随机临床试验

Comparative study of labour analgesia onset with injection of loading dose through epidural needle versus catheter: A prospective, double-blinded, randomised clinical trial.
PubMed 文献 · Eur J Anaesthesiol · 2024-10-16

该前瞻性双盲随机试验纳入200名健康未产产妇,比较经Tuohy针与单孔硬膜外导管注射负荷剂量(0.1%罗哌卡因+0.3 μg/ml舒芬太尼)的分娩镇痛起效时间。结果显示两组中位起效时间无显著差异(针组20[16-30]分钟 vs 导管组20[15-25]分钟,P=0.232),经硬膜外针注射并未缩短镇痛起效时间。

要点

  • 经硬膜外针注射负荷剂量未缩短分娩镇痛起效时间。
  • 两组中位起效时间均为20分钟,差异无统计学意义。
  • 硬膜外针注射与导管注射在起效时间上等效。

核心结论

  • 与经单孔硬膜外导管团注相比,经硬膜外针注射负荷剂量未缩短达到充分分娩镇痛的中位起效时间。

研究设计与样本

  • 共纳入200名要求硬膜外分娩镇痛的健康未产产妇,随机分为针组(n=100)和导管组(n=100)。
  • 针组经Tuohy针注射试验剂量3 ml(0.1%罗哌卡因+0.3 μg/ml舒芬太尼),3分钟后30秒内注射15 ml负荷剂量,随后置入导管;导管组置管后经导管以相同方式注射。
  • 主要结局为分娩镇痛起效时间(从给药至充分镇痛),充分镇痛定义为宫缩时视觉模拟评分≤10 mm。

主要发现

  • 针组中位起效时间20[IQR 16-30]分钟,导管组20[IQR 15-25]分钟,P=0.232,差异无统计学意义。

关键数值与推荐

  • 充分镇痛定义为宫缩时视觉模拟评分≤10 mm。
  • 试验剂量为3 ml 0.1%罗哌卡因+0.3 μg/ml舒芬太尼,负荷剂量为15 ml相同混合液。

临床怎么用

  • 经硬膜外针注射负荷剂量不能加快分娩镇痛起效,常规经导管给药即可。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Rapid onset of epidural analgesia is an important concern for the parturient. Commonly, the local anaesthetic mixture is administered through the epidural catheter. Drugs administered through the epidural needle might decrease the onset time and enhance the spread of medication within the epidural space. OBJECTIVES: The primary aim of this study was to compare the onset time of analgesia when a loading dose of dilute local anaesthetic opioid mixture was injected through either the Tuohy needle or a single end-hole epidural catheter. DESIGN: A prospective, double-blinded, randomised clinical trial. SETTING: Single university hospital, from November 2022 to August 2023. PARTICIPANTS: A total of 200 healthy nulliparous women who requested epidural analgesia for labour were randomly allocated to the needle group (n = 100) or the catheter group (n = 100). INTERVENTIONS: In the needle group, after identification of the epidural space, a test dose of 3 ml 0.1% ropivacaine with 0.3 μg ml-1 sufentanil was injected through the Tuohy needle followed 3 min later by a 15 ml loading dose of the same mixture over 30 s. Then the catheter was inserted into the epidural space. In the catheter group, after identification of the epidural space, a catheter was advanced into the epidural space and the ropivacaine/sufentanil mixture was injected in an identical manner though the catheter. MAIN OUTCOME MEARSURES: The primary outcome was the onset time of labour analgesia (defined as the time from drug administration to adequate analgesia). Adequate analgesia was defined as a visual analogue score 10 mm or less during uterine contractions. RESULTS: Median [IQR] onset time of labour analgesia did not differ significantly between the two groups (needle group: 20 [16 to 30] minutes; catheter group: 20 [15 to 25] minutes, P = 0.232). CONCLUSION: Compared with bolus injection though a single end-hole epidural catheter, injection through the epidural needle did not shorten the analgesia onset time for adequate labour analgesia. TRIAL REGISTRATION: ClinicalTrials.gov (NCT05594771).

来源:Eur J Anaesthesiol,查看原文。版权归原作者所有。

引用

  1. Chen X, Tang Y, Yu Q, et al. Comparative study of labour analgesia onset with injection of loading dose through epidural needle versus catheter: A prospective, double-blinded, randomised clinical trial. Eur J Anaesthesiol. 2024. PMID: 39744745. doi:10.1097/EJA.0000000000002077

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。