文献速递区域麻醉与超声疼痛医学

连续外周神经阻滞用于烧伤管理:281例烧伤患者结局与并发症的回顾性研究

Continuous peripheral nerve blocks for burn management: a retrospective study of outcomes and complications in 281 burn patients.
PubMed 文献 · Reg Anesth Pain Med · 2026-02-05

该回顾性观察研究纳入2018年1月至2023年7月美国烧伤协会认证的区域烧伤中心收治的281例接受连续外周神经阻滞的急性烧伤患者,共置入484根神经周围导管。导管相关感染率为1.2%(95%CI 0%~2.2%),患者感染率为2.1%(95%CI 0%~3.8%),与其它外科人群相当,且未发生神经损伤、血管损伤或局部麻醉药全身毒性。

要点

  • 烧伤患者连续神经周围导管感染率1.2%,患者感染率2.1%,与其它外科人群相当。
  • 33%患者因阻滞镇痛充分而无需手术室清创,可在床旁完成。
  • 中位导管留置6天,未记录神经损伤、血管损伤或局麻药全身毒性。

核心结论

  • 在急性烧伤患者中,连续神经周围导管的感染率与其它外科人群相当。

研究设计与样本

  • 回顾性观察研究,纳入2018年1月至2023年7月美国烧伤协会认证的区域烧伤中心收治的281例接受连续外周神经阻滞的急性烧伤患者,共置入484根神经周围导管。

主要发现

  • 队列中52%为男性,中位年龄39岁(IQR 30-55)。
  • 导管相关感染见于6根神经周围导管(1.2%,95%CI 0%~2.2%),涉及6例不同患者(2.1%,95%CI 0%~3.8%)。
  • 中位烧伤总面积5%(IQR 2-9%),20%患者有全层烧伤。
  • 最常用导管为锁骨下(49%)、腘窝坐骨神经(29%)、股神经(19%)和收肌管(17%)。
  • 33%患者因阻滞提供充分镇痛而无需手术室清创,中位导管使用时间6天(IQR 4-8),未记录神经损伤、毒性、血管损伤或局部麻醉药全身毒性。

临床怎么用

  • 连续外周神经阻滞可用于急性烧伤患者的疼痛管理,感染风险与其它外科人群相当。
  • 部分患者可借助阻滞镇痛在床旁完成清创,避免手术室清创。

局限性

  • 回顾性观察研究,来自单中心,可能存在选择偏倚和记录不全。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is scarce literature regarding the use of continuous peripheral nerve blocks in acute burn patients, who may be at higher risk for catheter-related complications, including infection. We sought to describe our center's experience and infection rate with continuous perineural catheters in the setting of pain management for patients suffering from burns. METHODS: A retrospective observational study was performed including all patients admitted to an American Burn Association-verified regional burn center between January 2018 and July 2023 who received a continuous peripheral nerve block for an acute burn injury. RESULTS: There were 281 patients in the study cohort who received 484 perineural catheters. The cohort was 52% men with a median age of 39 years (IQR 30-55). A catheter-associated infection, defined as a clinical diagnosis by the treating physicians requiring the need for treatment with antibiotics or surgical debridement, was identified in six perineural catheters (1.2%, 95% CI 0% to 2.2%) involving six different patients (2.1%, 95% CI 0% to 3.8%). The median total body surface area burned was 5% (IQR 2-9%) and 20% of patients had full-thickness burns. The most commonly used catheters were infraclavicular (49%), popliteal sciatic (29%), femoral (19%), and adductor canal (17%). One-third (33%) of patients did not require operating room debridement as the block provided sufficient analgesia for bedside debridement. The median duration of catheter use was 6 days (IQR 4-8). There were no documented cases of nerve injury or toxicity, vascular injury, or local anesthetic systemic toxicity. CONCLUSIONS: In our practice, continuous perineural catheters in the setting of acute burns are associated with an infection rate comparable to other surgical populations.

来源:Reg Anesth Pain Med,查看原文。版权归原作者所有。