文献速递产科麻醉气道管理

高流量鼻氧用于肥胖产妇全麻诱导的疗效:一项双中心前瞻性随机临床试验

Efficacy of high-flow nasal oxygenation during induction of general anaesthesia in parturients living with obesity: a two-centre, prospective, randomised clinical trial.
PubMed 文献 · Anaesthesia · 2024-11-26

该双中心前瞻性随机试验纳入BMI>30 kg.m-2的择期剖宫产全麻产妇,比较标准面罩与高流量鼻氧预给氧效果。主要结局为预给氧3分钟后动脉血氧分压,高流量鼻氧组显著高于标准面罩组,但差异无临床意义。高流量鼻氧可作为肥胖产妇快速序贯诱导预给氧的备选方案。

要点

  • 肥胖产妇全麻诱导预给氧3分钟后,高流量鼻氧组动脉血氧分压显著高于标准面罩组。
  • 高流量鼻氧组开始通气时呼气末氧浓度也显著高于标准面罩组。
  • 两组插管后动脉血二氧化碳分压及胎儿结局相似,差异无临床意义。

核心结论

  • 肥胖产妇全麻诱导预给氧时,高流量鼻氧较标准面罩提供更高的动脉血氧分压和呼气末氧浓度,但差异无临床意义。

研究设计与样本

  • 双中心前瞻性随机临床试验,纳入BMI>30 kg.m-2的择期剖宫产全麻产妇,随机分为标准面罩组(氧流量10 l.min-1)和高流量鼻氧组(氧流量50 l.min-1),共54例完成研究。

主要发现

  • 预给氧3分钟后动脉血氧分压:标准面罩组均值(SD)40.1(8.9)kPa,高流量鼻氧组53.8(9.7)kPa,p<0.001。
  • 开始通气时呼气末氧浓度:标准面罩组均值(SD)78.3(5.38)%,高流量鼻氧组86.2(5.10)%,p<0.001。
  • 插管后动脉血二氧化碳分压及胎儿结局两组相似。

临床怎么用

  • 肥胖产妇全麻快速序贯诱导时,高流量鼻氧可作为预给氧的备选方案。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: High-flow nasal oxygenation has been shown to improve oxygenation during induction of anaesthesia in parturients who are not obese. However, data on the efficacy of high-flow nasal oxygen in parturients living with obesity are lacking. This study investigated the effects of high-flow nasal oxygenation on pre-oxygenation and apnoea oxygenation during tracheal intubation in parturients living with obesity. METHODS: This prospective, randomised clinical trial was conducted at two tertiary hospitals and included parturients with BMI > 30 kg.m-2 undergoing scheduled caesarean delivery under general anaesthesia. Parturients were allocated randomly to standard facemask or high-flow nasal oxygen groups (oxygen flow rates 10 l.min-1 and 50 l.min-1, respectively). The primary outcome measure was arterial partial pressure of oxygen after 3 min of pre-oxygenation. RESULTS: 54 patients completed the study. The arterial partial pressure of oxygen after 3 min of pre-oxygenation was significantly lower in parturients allocated to the standard facemask group compared with those allocated to the high-flow nasal oxygen group (mean (SD) 40.1 (8.9) kPa vs. 53.8 (9.7) kPa, p < 0.001). End-tidal oxygen concentration on commencing ventilation was also lower in parturients allocated to the standard facemask group compared with those allocated to the high flow-nasal oxygen group (mean (SD) 78.3 (5.38)% vs. 86.2 (5.10)%, p < 0.001). The arterial partial pressure of carbon dioxide post tracheal intubation and fetal outcomes were similar in both groups. DISCUSSION: Pre-oxygenation using high-flow nasal oxygenation provided a higher arterial partial pressure of oxygen and end-tidal oxygen concentration during general anaesthesia induction than standard facemask oxygenation in parturients living with obesity; however, the differences were not clinically meaningful. High-flow nasal oxygenation may be considered as an alternative option for pre-oxygenation during rapid sequence induction in parturients living with obesity.

来源:Anaesthesia,查看原文。版权归原作者所有。

引用

  1. Zhou SQ, Lian JF, Zhou Y, et al. Efficacy of high-flow nasal oxygenation during induction of general anaesthesia in parturients living with obesity: a two-centre, prospective, randomised clinical trial. Anaesthesia. 2024. PMID: 39592199. doi:10.1111/anae.16492

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。