清醒气管插管的镇静方案:系统综述与网状Meta分析
该系统综述与网状Meta分析纳入48项随机对照试验共2837例患者,比较33种镇静方案用于清醒气管插管。总体插管成功率在各方案间无差异;任何镇静策略均优于安慰剂缩短插管时间,但排除高偏倚风险试验后差异消失;右美托咪定和硫酸镁可能降低动脉血氧去饱和风险,但证据质量低。结论:优化氧合、气道表面麻醉和操作技术可能比特定镇静方案更重要。
要点
- 各镇静方案的总体清醒气管插管成功率无显著差异。
- 任何镇静策略均优于安慰剂缩短插管时间,但证据质量低。
- 右美托咪定和硫酸镁可能减少氧去饱和,但排除高偏倚风险试验后无差异。
核心结论
- 为最大化清醒气管插管的有效性和安全性,优化氧合、气道表面麻醉和操作表现可能比任何特定镇静方案影响更大。
研究设计与样本
- 系统综述与频率学网状Meta分析,纳入48项随机对照试验共2837例患者,比较33种镇静方案。
主要发现
- 总体插管成功率(38项研究,2139例患者)在各镇静方案间无证据表明任一方案更优。
- 插管成功时间(24项研究,1745例患者)中任何镇静策略均优于安慰剂,但排除高偏倚风险试验后无差异。
- 各结局的证据质量均为低。
临床怎么用
- 清醒气管插管时应优先优化氧合、气道表面麻醉和操作技术,而非依赖特定镇静方案。
- 右美托咪定和硫酸镁可能有助于减少氧去饱和,但证据质量低,需结合临床判断使用。
局限性
- 各结局的证据质量均为低。
- 排除高偏倚风险试验后,插管时间和氧去饱和风险的差异消失。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Different sedation regimens have been used to facilitate awake tracheal intubation, but the evidence has not been synthesised robustly, particularly with respect to clinically important outcomes. We conducted a systematic review and network meta-analysis to determine the sedation techniques most likely to be associated with successful tracheal intubation, a shorter time to successful intubation and a lower risk of arterial oxygen desaturation. METHODS: We searched for randomised controlled trials of patients undergoing awake tracheal intubation for any indication and reporting: overall tracheal intubation success rate; tracheal intubation time; incidence of arterial oxygen desaturation; and other related outcomes. We performed a frequentist network meta-analysis for these outcomes if two or more sedation regimens were compared between included trials. We also performed a sensitivity analysis excluding trials with a high risk of bias. RESULTS: In total, 48 studies with 2837 patients comparing 33 different regimens were included. Comparing overall awake tracheal intubation success rates (38 studies, 2139 patients), there was no evidence suggesting that any individual sedation regimen was superior. Comparing times to successful tracheal intubation (1745 patients, 24 studies), any sedation strategy was superior to placebo. When we excluded trials with a high risk of bias, we found no evidence of a difference between any interventions for time to successful tracheal intubation. Thirty-one studies (1753 patients) suggested that dexmedetomidine and magnesium sulphate were associated with a reduced risk of arterial oxygen desaturation compared with other interventions, but excluding trials with a high risk of bias suggested no relevant differences between interventions. The quality of evidence for each of our outcomes was low. CONCLUSIONS: To maximise effective and safe awake tracheal intubation, optimising oxygenation, topical airway anaesthesia and procedural performance may have more impact than any given sedation regimen.
引用
- El-Boghdadly K, Desai N, Jones JB, et al. Sedation for awake tracheal intubation: A systematic review and network meta-analysis. Anaesthesia. 2024. PMID: 39468765. doi:10.1111/anae.16452
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。