文献速递气道管理

声门上气道装置的选择:随机对照试验的网络Meta分析

Choice of supraglottic airway devices: a network meta-analysis of randomised controlled trials.
PubMed 文献 · Br J Anaesth · 2024-10-15

主要结局为术后咽痛(POST)发生率,次要结局包括首次插入成功率、出血并发症和口咽漏气压(OLP)。结果显示LMA Ambu、Jcerity Endoscoper、LMA Blockbuster和LMA Baska Mask分别在POST、出血、首次插入成功和OLP方面排名最高,Air-Q和i-gel在多个结局中排名靠前。

要点

  • LMA Ambu在降低术后咽痛方面排名最高。
  • Jcerity Endoscoper在减少出血并发症方面排名最高。
  • i-gel在POST、出血和首次插入成功中均排名前六,但OLP排名较差。

核心结论

  • 数据支持在考虑以患者为中心的结局时使用LMA-Ambu、Jcerity-Endoscoper、Air-Q和i-gel。

主要发现

  • 基于可信区间排名,POST、出血并发症、首次插入成功和OLP的最高排名装置分别为LMA Ambu、Jcerity Endoscoper、LMA Blockbuster和LMA Baska Mask。
  • Air-Q和i-gel在多个结局中排名靠前,i-gel是唯一在POST、出血和首次插入成功均排名前六的装置,但OLP排名较差。

关键数值与推荐

  • 主要结局为术后咽痛(POST)发生率;次要结局为首次插入成功率、出血并发症和口咽漏气压(OLP)。
  • 基于可信区间创建排名顺序以指导临床决策。

临床怎么用

  • 临床选择SGA时可参考排名:优先考虑LMA-Ambu、Jcerity-Endoscoper、Air-Q和i-gel以改善患者中心结局。
  • 临床医生对这些装置的熟悉程度及其在麻醉实践中的持续推广将影响围术期患者体验。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Over the last two decades, significant research interest has led to the development of a wide variety of supraglottic airways (SGAs) for anaesthesia providers to choose from. METHODS: In this network meta-analysis, we analysed 111 studies, enrolling 12 045 patients undergoing airway management with 29 SGAs. We targeted outcomes that contribute to clinicians' choice of one SGA over another. The primary outcome was the incidence of postoperative sore throat (POST). Secondary outcomes were first-attempt insertion success, bleeding complications, and oropharyngeal leak pressure (OLP). Based on credible intervals, we created a 'rank order' to guide decision-making for clinicians. RESULTS: The highest-ranking devices based on credible intervals for POST, bleeding complications, first-attempt insertion success, and OLP were LMA Ambu, Jcerity Endoscoper, LMA Blockbuster, and LMA Baska Mask, respectively. Air-Q and i-gel ranked favourably across multiple outcomes, with i-gel being the only device to rank within the top six SGAs for POST, bleeding, and first-attempt success despite ranking poorly for OLP. CONCLUSIONS: Our data support the use of LMA-Ambu, Jcerity-Endoscoper, Air-Q, and i-gel when considering patient-centred outcomes. Clinician familiarity with these devices and their continued expansion into anaesthetic practice will have important implications on the perioperative patient experience. SYSTEMATIC REVIEW PROTOCOL: PROSPERO (CRD42022383136).

来源:Br J Anaesth,查看原文。版权归原作者所有。

引用

  1. Kanakaraj M, Bhat AD, Singh NP, et al. Choice of supraglottic airway devices: a network meta-analysis of randomised controlled trials. Br J Anaesth. 2024. PMID: 39406569. doi:10.1016/j.bja.2024.09.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。