I-gel与Fastrach喉罩作为成人插管装置的临床性能比较:系统综述与Meta分析
该系统综述与Meta分析纳入14项RCT共1340例成人插管患者,比较I-gel与Fastrach喉罩的插管和通气效果及安全性。结果显示Fastrach首次插管成功率更高,但I-gel在纤维支气管镜引导下首次插管成功率更优;总体插管成功率、插管时间、置入时间及并发症无显著差异。
要点
- Fastrach首次插管成功率显著高于I-gel(RR 0.81,95%CI 0.67-0.98)。
- 纤维支气管镜经I-gel引导时首次插管成功率优于Fastrach(RR 1.05,95%CI 1.01-1.11)。
- 总体插管成功率、置入时间、插管时间及并发症两组无显著差异。
核心结论
- Fastrach的首次插管成功率高于I-gel,但I-gel在纤维支气管镜引导下首次插管成功率更优。
- 总体插管成功率、置入时间、插管时间及并发症两组无显著差异。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、EMBASE、Scopus和Cochrane数据库,纳入14项比较I-gel与Fastrach用于成人插管的RCT,共1340例患者。
临床怎么用
- 在成人插管中,若追求较高首次插管成功率可优先选择Fastrach。
- 若计划使用纤维支气管镜引导插管,I-gel可能获得更好的首次插管成功率。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The supraglottic airway device (SGD) was introduced as a breakthrough in airway management. The Fastrach emerged as the first commercially available intubating SGD, drawing extensive investigation. I-gel is a more recent device that has gained popularity, can be used as an intubating SGD, and replaced Fastrach in many institutions. However, there is uncertainty regarding the comparison between these devices in terms of efficacy for intubation and ventilation, and safety in an airway rescue situation. METHODS: PubMed, EMBASE, Scopus, and Cochrane databases were searched for randomized controlled trials (RCTs) comparing I-gel and Fastrach SGD in adult patients undergoing intubation. The primary outcome was the first-pass success rate for tracheal intubation. Secondary outcomes were tracheal intubation time, SGD insertion time and success, and complications. We computed risk ratios (RRs) to assess binary end points and weighted mean differences (WMDs) for continuous outcomes, with corresponding 95% confidence intervals (CIs) for the primary outcome and its subgroup analysis ( P < .05 was considered statistically significant) and 99% CI after Bonferroni correction for the secondary outcomes ( P < .01 was considered statistically significant). RESULTS: This study included a total of 14 RCTs encompassing 1340 patients. The results indicated a significant difference in the first-pass success rate favoring Fastrach (RR, 0.81; 95% CI, 0.67-0.98; P = .03; I² = 91%). In the subgroup analysis, when a flexible scope was utilized through I-gel, providers achieved a better tracheal intubation first-pass success rate (RR, 1.05; 95% CI, 1.01-1.11; P = .03; I² = 0%), compared with the Fastrach. Overall intubation success rates (RR, 0.92; 99% CI, 0.82-1.04; P = .08, I² = 92%) and time (WMD - 1.03 seconds; 99% CI, -4.75 to 2.69; P = .48; I² = 84%) showed no significant difference irrespective of the device used. There was no significant difference regarding device insertion time by the providers (WMD -6.48 seconds; 99% CI, -13.23 to 0.27; P = .01; I 2 = 98%). Success rates of the providers' initial SGD insertion and complications such as sore throat (RR, 1.01; 99% CI, 0.65-1.57; P = .95, I² = 33%) and blood presence post-SGD removal (RR, 0.89; 99% CI, 0.42-1.86; P = .68, I² = 0%) showed no significant difference. CONCLUSIONS: Based on our findings, a higher first-pass success rate was observed with the use of Fastrach when compared to I-gel. However, the use of I-gel might result in a better intubation success rate with the flexible scope-guided intubation. There are no significant differences in performance in terms of the success rate for intubation overall, time for device insertion, or time to intubation or complications regardless of the device used.
引用
- Machado Assis ML, Batistella Zasso F, Pedrotti Chavez M, et al. Comparison of Clinical Performance of I-gel and Fastrach Laryngeal Mask Airway as an Intubating Device in Adults: A Systematic Review and Meta-Analysis. Anesth Analg. 2025. PMID: 39259690. doi:10.1213/ANE.0000000000007000
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。