胸CT评估肋骨骨折竖脊肌平面镇痛导管位置
单中心回顾性队列研究筛查2020年1月至2022年7月因创伤性肋骨骨折入住外科ICU的成人,纳入接受连续竖脊肌平面(ESP)镇痛并后续行胸部CT的15例患者(18根导管)。主要结局为导管移出ESP的比例,结果显示16/18根导管位于ESP外,中位导管尖端至最近横突(或ESP)距离矢状面23.20 mm、轴面25.05 mm。
要点
- 多数留置ESP导管在置入后数日位于筋膜平面浅层。
- 导管尖端至ESP中位距离矢状面23.20 mm、轴面25.05 mm。
- 需前瞻性研究探讨导管移位的预防措施。
核心结论
- 多数ESP导管在置入后数日位于筋膜平面浅层,中位距离ESP约23至25 mm。
研究设计与样本
- 单中心回顾性队列研究,筛查160份病历,最终纳入15例患者共18根导管。
主要发现
- 18根导管中16根位于ESP外,其中14根报告为肌内、4根为皮下。
- 导管尖端至最近横突(或ESP)中位距离矢状面23.20 mm、轴面25.05 mm。
临床怎么用
- 对留置ESP镇痛导管患者,应关注导管可能移位至筋膜平面浅层而影响镇痛效果。
局限性
- 样本量小(15例患者18根导管),为单中心回顾性设计,仅纳入后续行胸部CT者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Continuous erector spinae plane (ESP) analgesia is a common adjuvant for patients with traumatic rib fracture pain and success relies on the ESP catheter remaining within the correct fascial plane for the duration of its placement. However, knowledge on postplacement position of indwelling ESP catheters is largely absent. We hypothesized that migration of over-the-needle ESP catheters was common and detectable with coincidental postprocedure CT. METHODS: In this single-center retrospective cohort study, adults admitted to the surgical intensive care unit for traumatic rib fractures between January 2020 and July 2022 were screened. Those receiving continuous ESP analgesia via indwelling catheter and undergoing subsequent chest CT were included. The primary outcome was the proportion of catheters that migrated outside the ESP. The secondary outcome was the distance between the catheter tip and the nearest transverse process (TP) or fascial plane. RESULTS: 160 medical records were screened for eligibility and 15 patients (18 catheters) met the inclusion criteria. 16 of 18 catheters reviewed were found outside the ESP. Furthermore, catheter position was reported as intramuscular in 14 catheters and subcutaneous in 4 catheters. The median distance between catheter tip and the nearest TP (or the ESP) was 23.20 mm sagittally and 25.05 mm axially. CONCLUSIONS: Most ESP catheters were found superficial to the fascial plane in the days following their placement. The median distance between the catheter and the ESP is between 23 and 25 mm. Prospective studies should address catheter migration concerns and propose solutions to this common issue.
引用
- Wu M, Barrak C, Forrest P, et al. Assessment of catheter position using chest CT in adults undergoing erector spinae plane analgesia for rib fractures: a retrospective cohort study. Reg Anesth Pain Med. 2025. PMID: 38969508. doi:10.1136/rapm-2024-105673
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。