文献速递气道管理

高角度无通道与有通道视频喉镜用于预计困难气道清醒气管插管首次尝试成功率的随机对照试验

First-attempt awake tracheal intubation success rate using a hyperangulated unchannelled videolaryngoscope vs. a channelled videolaryngoscope in patients with anticipated difficult airway: a randomised controlled trial.
PubMed 文献 · Anaesthesia · 2024-07-29

本研究为随机对照试验,纳入90例预计困难气道需在局部麻醉和清醒镇静下清醒气管插管的成人患者,比较C-MAC D-Blade与Airtraq视频喉镜。结果显示C-MAC D-Blade组首次尝试插管成功率高于Airtraq组(84% vs 62%,p=0.006),但总体成功率无显著差异(100% vs 96%,p=0.494)。

要点

  • 预计困难气道清醒插管时,C-MAC D-Blade首次尝试成功率高于Airtraq。
  • 两种视频喉镜的总体插管成功率无显著差异。
  • C-MAC D-Blade组需要第二次尝试的比例低于Airtraq组。

核心结论

  • 在预计困难气道患者中,C-MAC D-Blade视频喉镜的首次清醒气管插管成功率高于Airtraq视频喉镜。
  • 两种视频喉镜的总体气管插管成功率无显著差异。

研究设计与样本

  • 随机对照试验,纳入90例预计困难气道的成人患者(年龄≥18岁),随机分配至C-MAC D-Blade组或Airtraq组。
  • 患者接受局部麻醉和清醒镇静下的清醒气管插管,主要终点为首次尝试气管插管成功率。

主要发现

  • C-MAC D-Blade组首次尝试插管成功率为84%(38/45),Airtraq组为62%(28/45),差异有统计学意义(p=0.006)。
  • C-MAC D-Blade组第二次和第三次尝试插管比例分别为9%(4/45)和7%(3/45),Airtraq组分别为31%(14/45)和2%(1/45)(p=0.006)。
  • 总体插管成功率C-MAC D-Blade组为100%(45/45),Airtraq组为96%(43/45),差异无统计学意义(p=0.494)。

临床怎么用

  • 对于预计困难气道需清醒气管插管的患者,可优先考虑使用C-MAC D-Blade视频喉镜以提高首次尝试成功率。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: There is uncertainty about the optimal videolaryngoscope for awake tracheal intubation in patients with anticipated difficult airway. The use of channelled and unchannelled videolaryngoscopy has been reported, but there is a lack of evidence on which is the best option. METHODS: We conducted a randomised clinical trial to compare the efficacy of the C-MAC D-Blade® vs. Airtraq® in adult patients (aged ≥ 18 y) scheduled for elective or emergency surgery under general anaesthesia with anticipated difficult airway who required awake tracheal intubation under local anaesthesia and conscious sedation. The primary endpoint was the first-attempt tracheal intubation success rate. Secondary outcomes included the overall success rate; number of tracheal intubation attempts; Cormack and Lehane glottic view; level of difficulty (visual analogue score); patient discomfort (visual analogue score); and incidence of complications. RESULTS: Ninety patients (70/90 male (78%); mean (SD) age 65 (12) y) with anticipated difficult airways were randomly allocated to C-MAC D-Blade or Airtraq videolaryngoscopy. First-attempt successful tracheal intubation rate was higher in patients allocated to the C-MAC D-Blade group compared with those allocated to the Airtraq group (38/45 (84%) vs. 28/45 (62%), respectively; p = 0.006). The proportion of patients' tracheas that were intubated at the second and third attempt was 4/45 (9%) and 3/45 (7%) in those allocated to the C-MAC D-Blade group compared with 14/45 (31%) and 1/45 (2%) in those allocated to the Airtraq group (p = 0.006). There was no significant difference in overall tracheal intubation success rate (C-MAC D-Blade group 45/45 (100%) vs. Airtraq group 43/45 (96%), p = 0.494). DISCUSSION: In patients with anticipated difficult airway, first-attempt awake tracheal intubation success rate was higher with the C-MAC D-Blade compared with Airtraq laryngoscopy. No difference was found between the two videolaryngoscopes in overall tracheal intubation success rate.

来源:Anaesthesia,查看原文。版权归原作者所有。

引用

  1. Taboada M, Fernández J, Estany-Gestal A, et al. First-attempt awake tracheal intubation success rate using a hyperangulated unchannelled videolaryngoscope vs. a channelled videolaryngoscope in patients with anticipated difficult airway: a randomised controlled trial. Anaesthesia. 2024. PMID: 39075801. doi:10.1111/anae.16389

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。