注射温度对腰麻布比卡因剂量需求的影响:随机双盲研究
将布比卡因加温至体温可减少约16%的剂量需求(95%CI 7%-23%)。
要点
- 37°C布比卡因腰麻剖宫产ED50为6.7 mg,低于24°C的8.1 mg。
- 加温至体温可减少约16%的布比卡因剂量需求。
- 室温组相对体温度组效力比为0.84(95%CI 0.77-0.93)。
核心结论
- 将高比重布比卡因加温至体温可降低剖宫产腰麻的剂量需求约16%(95%CI 7%-23%)。
研究设计与样本
- 采用改良上下序贯法,起始剂量10 mg,步长1 mg,计算ED50。
主要发现
- 室温组相对体温度组效力比为0.84(95%CI 0.77-0.93)。
临床怎么用
- 剖宫产腰麻时可考虑将布比卡因加温至体温以减少所需剂量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Increasing the temperature of intrathecal local anesthetics has been shown to increase the speed of onset and block height of spinal anesthesia. However, how this influences dose requirement has not been fully quantified. The aim of this study was to determine and compare the effective dose for anesthesia for cesarean delivery in 50% of patients (ED 50 ) of intrathecal bupivacaine given at temperatures of 37 °C (body temperature) or 24 °C (room temperature). METHODS: Eighty healthy parturients having elective cesarean delivery under combined spinal-epidural anesthesia were randomly assigned to receive intrathecal hyperbaric bupivacaine stored at 37 °C (body temperature group) or 24 °C (room temperature group). The first subject in each group received a bupivacaine dose of 10 mg. The dose for each subsequent subject in each group was varied with an increment or decrement of 1 mg based on the response (effective or noneffective) of the previous subject. Patients for whom the dose was noneffective received epidural supplementation after data collection with lidocaine 2% as required until anesthesia was sufficient for surgery. Values for ED 50 were calculated using modified up-down sequential analysis with probit analysis applied as a backup sensitivity analysis. These values were compared and the relative mean potency was calculated. RESULTS: The ED 50 (mean [95% confidence interval, CI]) of intrathecal hyperbaric bupivacaine was lower in the body temperature group (6.7 [5.7-7.6] mg) compared with the room temperature group (8.1 [7.7-8.6] mg) ( P < .05). The relative potency ratio for intrathecal bupivacaine for the room temperature group versus the body temperature group was 0.84 (95% CI, 0.77-0.93). CONCLUSIONS: Warming hyperbaric bupivacaine to body temperature reduced the dose requirement for spinal anesthesia for cesarean delivery by approximately 16% (95% CI, 7%-23%).
引用
- Zhao YP, Zhang XF, Qian J, et al. Randomized Double-Blind Study of the Effect of Injectate Temperature on Intrathecal Bupivacaine Dose Requirement in Spinal Anesthesia for Cesarean Delivery. Anesth Analg. 2024. PMID: 38870069. doi:10.1213/ANE.0000000000007095
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。